CUB5B000 Red Lion Controls, CUB5B000 Datasheet
![COUNTER/RATE IND DUAL RD/GN BKLT](/photos/6/45/64504/cub5b000_sml.jpg)
CUB5B000
Specifications of CUB5B000
Available stocks
CUB5B000 Summary of contents
Page 1
... The display can be toggled either manually or automatically between the selected displays. The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in two versions, reflective (CUB5R000) and backlight (CUB5B000). The backlight version is user selectable for green or red backlighting with variable display intensity. ...
Page 2
... ETER 1. DISPLAY: 8 digit LCD 0.46" (11.7 mm) high digits CUB5R000: Reflective LCD with full viewing angle CUB5B000: Transmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER: Input voltage range +28 VDC with short circuit and input polarity protection ...
Page 3
O P PTIONAL LUG ADDING OPTION CARDS The CUB5 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below. The plug-in cards, that are ...
Page 4
I NSTALLING The Plug-in cards are separately purchased option cards that perform specific functions. The cards plug into the main circuit board of the meter. After installing the cards, replace the rear cover before wiring the meter. Comms or ...
Page 5
INPUT WIRING CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter application, the power common must be suitably isolated from hazardous live earth referenced voltage; or ...
Page 6
R EVIEWING THE KEY DISPLAY MODE OPERATION SEL Index display through enabled values RST Resets count display(s) and/or outputs OPERATING MODE DISPLAY DESIGNATORS R “ ” the left of the display is the rate value. - Counter ...
Page 7
MODULE 1-INPUt SEL INP A-b CntA dP CntA ScF CntA rSt Count Counter A Counter A Counter A Mode Decimal Point Scale Factor Reset Action Shaded area selections only apply when Counter B is enabled (Dual ...
Page 8
... Note: * indicates Edge Triggered function. Other functions are Level Active (maintained) USEr ASN Count A The User Input Assignment is only active when Counter B is enabled and the User Input performs a Reset, Inhibit or Store function on one or both counters ATE ETUP ARAMETERS PARAMETER MENU ...
Page 9
SCALING FOR RATE INDICATION To scale the rate, enter a Scaling Display value with a corresponding Scaling Input value. These values are internally plotted to a display value of 0 and input value of 0.0 Hz. A linear relationship is ...
Page 10
MODULE 3-dSPLAY SEL SEL Enb RSt Enb Front Panel Front Panel Display Scroll Display Select Counter Enable Reset Enable FRONT PANEL DISPLAY SELECT ENABLE (SEL) SEL Enb yES NO yES yES The selection allows ...
Page 11
MODULE 4-SEtPt SP2 Only SEL SPt SEL SP2 Enb SPn ASN Setpoint Setpoint 2 Select Enable Assignment SPn P-UP SPn tYPE Setpoint Output Setpoint Power-up Boundary State Type The Setpoint Output Parameters are only active when ...
Page 12
SETPOINT OUTPUT TIME-OUT SPn tOUt 599 001 This parameter is only active if the Setpoint Action is set to time out ( Enter the value in seconds that the Setpoint ...
Page 13
MODULE 5-SEriAL SEL bAUd dAtA Baud Rate Data Bit The Serial Setup Parameters are only active when one of the optional serial communication/programming cards is installed in the meter. Refer to the CUB5USB bulletin for details ...
Page 14
Copy Procedure: 1. Connect the master and receiver using the appropriate copy cable. 2. Apply power to the meters. The receiving meter must be operating in the normal display mode (not programming mode the master meter, enter programming ...
Page 15
... Ready The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon ...
Page 16
CUB5 PROGRAMMING QUICK OVERVIEW 16 ...