H7CX-AD DC12-24 Omron, H7CX-AD DC12-24 Datasheet - Page 17

COUNTER DIGITAL 12-24VDC SCREW

H7CX-AD DC12-24

Manufacturer Part Number
H7CX-AD DC12-24
Description
COUNTER DIGITAL 12-24VDC SCREW
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-AD DC12-24

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-AD DC12-24
H7CXADDC1224
Q2219129
Z2365
Operating Procedures
■ Setting Procedure Guide
Setting for Counter Operation
(1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter)
Note: 1. At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration.
Setting for Tachometer Operation
Note: At the time of delivery, the H7CX is set to the 2-stage counter (1-stage counter for H7CX-AU@ models) configuration.
2. Set to output 2 time when using as a 2-stage counter or batch counter.
When Using Basic Settings Only
When Using Settings Other than the Above
When Using Basic Settings Only
Basic Settings
Other Settings
• Counting speed (30 Hz, 5 kHz)
• Input mode (UP, DOWN)
• Output mode (N, F, C, K-1)
• One-shot output time (0.5 s, 0.05 s) (See note 2.)
• Reset input signal width (20 ms, 1 ms)
• NPN/PNP input mode (NPN, PNP)
All the functions can be set with the operation keys.
• Input mode (UP/DOWN A, UP/DOWN B, UP/DOWN C)
• Output mode (R, P, Q, A, K-2, D, L, H)
• One-shot output time (except for 0.5 s and 0.05 s) (See note 2.)
Basic Settings
• Counting speed (30 Hz, 10 kHz)
• Output mode (HI-LO, AREA, HI-HI, LO-LO)
• Average processing (OFF, 2, 4, 8 times)
• NPN/PNP input mode (NPN, PNP)
For details on the setting methods, refer to page 19.
When Using Advanced Functions
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
• Decimal point position
• Prescale value
• Auto-zero time
• Startup time
• Display color
• Output allocation
• Key protect level
Advanced Functions
For details on the setting methods, refer to page 31.
The settings can be performed easily with the DIP switch.
The settings can be performed easily with the DIP switch.
For details on the setting methods, refer to page 18.
For details on the setting methods, refer to page 30.
OFF
When Using Advanced Functions
ON
OFF
ON
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
• Dual count calculating mode
• Output 1 time (for 2-stage counter)
• Decimal point position
• Prescale value
• Display color
• Output allocation
• Key protect level
Advanced Functions
For details on the setting methods, refer to page 19.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
H7CX-A