H7CX-AD DC12-24 Omron, H7CX-AD DC12-24 Datasheet - Page 33

COUNTER DIGITAL 12-24VDC SCREW

H7CX-AD DC12-24

Manufacturer Part Number
H7CX-AD DC12-24
Description
COUNTER DIGITAL 12-24VDC SCREW
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-AD DC12-24

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-AD DC12-24
H7CXADDC1224
Q2219129
Z2365
Output Allocation (otst)
When using H7CX-AU@ models as 2-stage counter, each output can
be flexibly allocated to either stage 1 or 2.
Transistor output placed for SV1 and contact output for SV2 or vice
verse, as in the following table.
H7CX-AU/-AUD1
H7CX-AUSD1
Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key-
protect switch after the H7CX is mounted to the panel.
Note: Changing mode to configuration selection mode (
off
on
off
on
KP-1 (default setting)
KP-2
KP-3
KP-4
KP-5
Note: Factory-set to OFF
(See note)
Level
Transistor (12-13)
Contact (3, 4, 5)
Transistor (12-13)
Transistor with diode
(3, 4, 5)
OFF
Key protect indicator
ON
OUT1
OUT1
Meaning
Contact (3, 4, 5)
(3, 4, 5)
Transistor (12-13)
Transistor (12-13)
Transistor with diode
No
No
No
No
No
Changing mode
OUT2
OUT2
(See note.)
MODE
+
1
1 s min.) or function setting mode (
Yes
Yes
Yes
Yes
No
Switching display
during operation
Details
Yes
No
Yes
No
No
Reset key
MODE
3 s min.).
Up/down key (Up key for
Yes
Yes
No
No
No
6-digit models)
H7CX-A
33