H7CX-AD DC12-24 Omron, H7CX-AD DC12-24 Datasheet - Page 26

COUNTER DIGITAL 12-24VDC SCREW

H7CX-AD DC12-24

Manufacturer Part Number
H7CX-AD DC12-24
Description
COUNTER DIGITAL 12-24VDC SCREW
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-AD DC12-24

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-AD DC12-24
H7CXADDC1224
Q2219129
Z2365
Applicable Counters
K-2 mode: H7CX-A11@, H7CX-A@, and H7CX-AW@
D mode: H7CX-A11@, H7CX-A@, and H7CX-AW@
L mode: H7CX-A11@, H7CX-A@, and H7CX-AW@
H mode: H7CX-AW@
Note: 1. Counting cannot be performed during reset/reset 1 input.
Output
setting
mode
2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output
4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
will turn ON again for the duration of the output time setting once the power supply has recovered.
K-2
D
H
L
Reset/
reset 1
999999
Set
value 2
Set
value 1
−99999
OUT1
OUT2
Reset/
reset 1
999999
Set
value 2
Set
value 1
−99999
OUT1
OUT2
Reset/
reset 1
999999
Set
value 2
Set
value 1
−99999
OUT1
OUT2
Reset/
reset 1
999999
Set
value 2
Set
value 1
−99999
OUT1
OUT2
0
0
0
0
UP/DOWN A, B, C
Input mode
Self-holding
output
Instantaneous
(equals) output
The display continues to in-
crease/decrease until the over-
flow or underflow value is
reached. One-shot output only.
The display continues to in-
crease/decrease until the over-
flow or underflow value is
reached. The outputs are ON
while the count is equal.
The display continues to in-
crease/decrease until the over-
flow or underflow value is
reached.
OUT1 is held while the present
value is less than or equal to set
value 1. OUT2 is held while the
present value is greater than or
equal to set value 2.
The display continues to in-
crease/decrease until the over-
flow or underflow value is
reached.
OUT1 is held while the present
value is greater than or equal to
set value 1. OUT2 is held while
the present value is greater than
or equal to set value 2.
Note:
H mode is available only when
using a 6-digit model as a 2-
stage counter.
Operation after count
One-shot
output
completion
(The one-shot output time
can be set in the range 0.01
to 99.99s.)
H7CX-A
26