Specifications of H7CX-A114D1 DC12-24/AC24

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
12 V ~ 24 VDC, 24VAC
Display Type
*
No. Of Digits / Alpha
4
Meter Function
Counter
Signal Input Type
PNP/NPN
Supply Voltage Max
24VDC
Character Size
11.5mm
Ip/nema Rating
IP66 / NEMA 4
Panel Cutout Height
45mm
Supply Voltage Min
12VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A114D1DC12-24/AC24
H7CXA114D1DC1224AC24
Output Mode Settings
Output
setting
mode
(LO-LO)
(AREA)
(HI-LO)
(HI-HI)
Upper
Upper
Lower
lower
Area
limit
limit
limit
and
Condition
condition
condition
for OUT1
for OUT2
ON
ON
OUT1 set value ≤ measurement value ≤ OUT2 set
value
measurement value < OUT1 set value
or
measurement value > OUT2 set value
OUT1 set value ≤ OUT2 set value
(Upper-limit) OUT1 set value
(Lower-limit) OUT1 set value
(Upper-limit) OUT2 set value
(Lower-limit) OUT2 set value
(Lower-limit) OUT1 set value
ON condition for OUT1: Measurement value ≥ OUT1 set value
ON condition for OUT2: Measurement value ≥ OUT2 set value
ON condition for OUT1: measurement value ≤ OUT1 set value
ON condition for OUT2: measurement value ≥ OUT2 set value
ON condition for OUT1: Measurement value ≤ OUT1 set value
ON condition for OUT2: Measurement value ≤ OUT2 set value
(Upper-limit) OUT2 set value
Measurement value
Measurement value
Measurement value
Measurement value
OUT1 set value
OUT2 set value
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT2 set value ≤ measurement value ≤ OUT1 set
value
measurement value < OUT2 set value
or
measurement value > OUT1 set value
OUT1 set value > OUT2 set value
H7CX-A