H7CX-A114D1 DC12-24/AC24 Omron, H7CX-A114D1 DC12-24/AC24 Datasheet - Page 62

COUNTER 11-PIN 12VDC 4DIGIT SPDT

H7CX-A114D1 DC12-24/AC24

Manufacturer Part Number
H7CX-A114D1 DC12-24/AC24
Description
COUNTER 11-PIN 12VDC 4DIGIT SPDT
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-A114D1 DC12-24/AC24

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
12 V ~ 24 VDC, 24VAC
Display Type
*
No. Of Digits / Alpha
4
Meter Function
Counter
Signal Input Type
PNP/NPN
Supply Voltage Max
24VDC
Character Size
11.5mm
Ip/nema Rating
IP66 / NEMA 4
Panel Cutout Height
45mm
Supply Voltage Min
12VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A114D1DC12-24/AC24
H7CXA114D1DC1224AC24
Safety Precautions (H7CX-R)
■ Precautions for Safe Use
Changing the Measurement Value
The H7CX-R uses a constant read-in system, so the output status is
affected when the comparison values are changed during operation
such that the present measurement value falls within the range of the
upper- and lower-limit comparison values.
Turning ON the Power using the
Factory Settings
When the power is turned ON using the factory settings, the output
will turn ON after 999.9 s if no pulses are received as count input.
■ Precautions for Correct Use
Comparison Value Settings
In upper and lower limit output mode, if the comparison value setting
is such that comparison value 1 ≥ comparison value 2, the output will
always be ON.
Using the Prescaling Function
Setting the prescale value incorrectly may result in incorrect counting
operation. Be sure to set the prescale value correctly.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
H7CX