H7CX-AWSD DC12-24 Omron, H7CX-AWSD DC12-24 Datasheet - Page 35

COUNTER SCREW-TERM 6DIGT 1/16DIN

H7CX-AWSD DC12-24

Manufacturer Part Number
H7CX-AWSD DC12-24
Description
COUNTER SCREW-TERM 6DIGT 1/16DIN
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-AWSD DC12-24

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
12 V ~ 24 V
Display Type
*
No. Of Digits / Alpha
6
Signal Input Type
PNP/NPN
Supply Voltage Max
24V
Panel Cutout Height
48mm
Supply Voltage Min
12V
Panel Cutout Width
48mm
Connector Type
Screw Terminal
Counter Supply Voltage
12-24VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-AWSDDC12-24
H7CXAWSDDC1224
Output Mode Settings
Output
setting
mode
(LO-LO)
(AREA)
(HI-LO)
(HI-HI)
Upper
Upper
Lower
lower
Area
limit
limit
limit
and
Condition
condition
condition
for OUT1
for OUT2
ON
ON
OUT1 set value ≤ measurement value ≤ OUT2 set
value
measurement value < OUT1 set value
or
measurement value > OUT2 set value
OUT1 set value ≤ OUT2 set value
(Upper-limit) OUT1 set value
(Lower-limit) OUT1 set value
(Upper-limit) OUT2 set value
(Lower-limit) OUT2 set value
(Lower-limit) OUT1 set value
ON condition for OUT1: Measurement value ≥ OUT1 set value
ON condition for OUT2: Measurement value ≥ OUT2 set value
ON condition for OUT1: measurement value ≤ OUT1 set value
ON condition for OUT2: measurement value ≥ OUT2 set value
ON condition for OUT1: Measurement value ≤ OUT1 set value
ON condition for OUT2: Measurement value ≤ OUT2 set value
(Upper-limit) OUT2 set value
Measurement value
Measurement value
Measurement value
Measurement value
OUT1 set value
OUT2 set value
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT2 set value ≤ measurement value ≤ OUT1 set
value
measurement value < OUT2 set value
or
measurement value > OUT1 set value
OUT1 set value > OUT2 set value
H7CX-A