PAXLIT00 Red Lion Controls, PAXLIT00 Datasheet - Page 3

METER AC CURRENT 5A 3 1/2-DIGIT

PAXLIT00

Manufacturer Part Number
PAXLIT00
Description
METER AC CURRENT 5A 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Ammeterr
Datasheets

Specifications of PAXLIT00

Measuring Range
0 ~ 5A
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
115VAC,230 VAC
No. Of Digits / Alpha
3-1/2
Meter Function
AC Ammeter
Meter Range
0A To 5A
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
115V
Accuracy
±0.5% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
2.5 mA
Function
Ammeter
Meter Type
AC Current
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
0 to 5 A
Special Features
Multi-Range Unit
Standards
cULus Listed, CE Marked
Temperature, Operating
0 to 60 °C
Voltage, Supply
115/230 VAC
Weight
0.65 lbs
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
RLC109
UNITS LABEL KIT (PAXLBK)
using the Units Label Kit. The backlight is controlled by a DIP switch.
1. DISPLAY: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment red LED. Decimal
2. POWER: 115/230 VAC, switch selectable. Allowable power line variation
3. SIGNAL INPUT:
4. ACCURACY: ±(0.5% of reading + 5 digits).
5. OVER-RANGE INDICATION: is indicated by blanking 3 least significant
6. MAX SHUNT CURRENT: 50 Amps for 1 sec.; 8 Amps continuous.
7. ENVIRONMENTAL CONDITIONS:
8. RESPONSE TIME TO STEP CHANGE INPUT: 1 sec. nominal
9. READING RATE: 2.5 readings/sec., nominal
10. CERTIFICATIONS AND COMPLIANCES:
G
A
Each meter has a units indicator with backlighting that can be customized
points inserted before 1st, 2nd, or 3rd least significant digits by DIP switch
selection.
±10%, 50/60 Hz, 6 VA.
Isolation: 2300 Vrms for 1 min. between input and supply
Working Voltage: 300 V max., CAT II
Range: 0 to 5 Amps AC @ 45 to 400 Hz
Resolution: 2.5 mA
Working Voltage: 300 V max., CAT II
digits.
Caution: In circuits where fault currents can exceed the maximum shunt
Operating Temperature: 0° to 60 °C
Storage Temperature: -40° to 80 °C
Operating and Storage Humidity: 85% max. relative humidity (non-
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30g’s, 11 msec in 3
Altitude: Up to 2000 meters
SAFETY
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
IECEE CB Scheme Test Report # 04ME11209-20041018
current, a fast-blow fuse should be installed in series with the input signal.
Otherwise, a slow blow 8 Amp fuse is recommended that will allow for
start-up over current situations, while still protecting the instrument.
condensing)
direction for 1.5 hours, 2g’s.
directions.
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
CCESSORIES
ENERAL
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
M
ETER
S
PECIFICATIONS
3
Notes:
11. CONNECTIONS: High compression cage-clamp terminal block
12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use.
13. WEIGHT: 0.65 lbs. (0.24 Kg)
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
Installation Category II, Pollution Degree 2. One piece bezel/case. Flame
resistant. Panel gasket and mounting clip included.
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Voltage dip/interruptions
Emissions:
Emissions
recovers.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 55011
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion B
10 V/m
Criterion B
2 kV power
2 kV signal
Criterion A
1 kV L-L,
Criterion A
3 V/rms
Criterion A
0.5 cycle; 40 % variation
Class B
2 kV L&N-E power