179610-1 TE Connectivity, 179610-1 Datasheet - Page 4

AMP CT CRIMP-2 REC CONT. L/P

179610-1

Manufacturer Part Number
179610-1
Description
AMP CT CRIMP-2 REC CONT. L/P
Manufacturer
TE Connectivity
Datasheets

Specifications of 179610-1

Product Type
Contact
Termination Method To Wire/cable
Crimp
Contact - Rated Current (a)
2
Operating Voltage Reference
AC/DC, AC, DC
Operating Voltage (vac)
125
Operating Voltage (vdc)
125
Wire/cable Size (awg)
26 – 30
Mating Retention
Without
Contact Type
Socket
Contact Plating, Mating Area, Material
Pre-Tin
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Operating Temperature (°c [°f])
-30 – +105 [-22 – +221]
Applies To
Wire/Cable
Accepts Wire Insulation Diameter, Range (mm [in])
0.65 – 1.35 [0.0255 – 0.053]
Application Use
Wire-to-Board, Wire-to-Board / Wire-to-Wire, Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)
Packaging Method
Loose Piece
ASHL-0005- ES REV B
3.8.1 (1)
3.8.1 (2)
3.8.1 (3)
3.8.1 (4)
3.8.1 (5)
Para.
3.8
Test Requirements and Procedures Summary:
Connector
Mating/
Unmating Force
Tensile Strength
of Wire
Termination
Contact
Mounting Force
Contact
Retention Force
Post Retention
Force
Test Items
AMP Shanghai Ltd.
Tyco Electronics
14.7N Max.
14.7N Min. per contact.
14.7N Min. per contact.
Initial and 30
No. of
Pos.
The value in parenthesis shows the ones for
post header for relay use obtained by
measurement on lock side.
10
11
12
13
14
15
2
3
4
5
6
7
8
9
# 22 AWG
# 24 AWG
# 26 AWG
# 28 AWG
# 30 AWG
Wire Size
Mechanical Performance Requirements
(AWG)
[Max.] Unit: N
63.7 (104.9)
67.7 (110.8)
71.6 (116.7)
75.5 (122.6)
80.4 (128.5)
th
24.5 (49.0)
30.4 (56.9)
34.3 (63.7)
39.2 (69.6)
43.1 (75.5)
47.1 (81.4)
51.0 (87.3)
54.9 (93.2)
59.8 (99.0)
Insertion
Cycle.
Fig. 2 (To be continued)
Requirements
4 of 11
PAGE
Tensile Strength
Min. (Unit: N)
[Min.] Unit: N
49.0
29.4
19.6
14.7
9.8
Extraction
(12.7)
(16.7)
(7.8)
(9.8)
13.7
Document No.
4.9
6.9
9.8
108-5408
Subject terminated connector
and header to mate and unmate
to measure the force required to
engage and disengage by
operating the head at a rate of
50 mm a minute. Record by
using autograph.
Apply a pull-off load to
terminated wire of contact
secured on the tester, at a rate
of 100mm a minute.
The load is applied in the axial
and lateral directions as
specified.
Measure the force required to
mount contact on housing.
Apply axial load to contact by
operating at a rate of 100mm a
minute.
Apply an axial pull-off load to
post contact mounted on
housing and measure the force
required to dislodge post from
the housing. See Fig. 5.
Procedures
REV
B
LOC
ES

Related parts for 179610-1