LM9832CCVJD National Semiconductor, LM9832CCVJD Datasheet - Page 38

IC SCANNER CLR USB IMAGE 100TQFP

LM9832CCVJD

Manufacturer Part Number
LM9832CCVJD
Description
IC SCANNER CLR USB IMAGE 100TQFP
Manufacturer
National Semiconductor
Datasheet

Specifications of LM9832CCVJD

Number Of Bits
14
Number Of Channels
3
Voltage - Supply, Analog
5V
Voltage - Supply, Digital
5V
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-
Other names
*LM9832CCVJD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM9832CCVJD
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM9832CCVJD
Manufacturer:
NS
Quantity:
2 849
Applications Information
CCFL light source.
The second consideration is the stepsize calculation. Using the
ITA’s dual timebases affects the stepsize required to produce an
image with the correct vertical resolution. The solution is to calcu-
late the stepsize using the traditional formula, then multiply it by
the factor (ITA+1)/ITA:
14.0 QUESTIONS AND ANSWERS
Q Where is calibration done?
A Calibration is done on the host computer.
Q Does the LM9832 support 800dpi sensors? 400dpi? XXXdpi?
A Yes. The LM9832 will support any sensor up to a maximum of
15.0 GENERAL NOTES AND TROUBLESHOOTING TIPS
(mclk_divider)(HDPI_divider)(ITA) must be greater than or equal
to 6. If this condition is not met, the LM9832 will not work.
Make sure the gamma tables are programmed with a valid
gamma curve.
Make sure the multiplier gain coefficients are loaded and correct.
(Remember, a gain coefficient of 0 means a GAIN of x0, not x1. If
the gain coefficient = 0 the output code will always be 0.)
Remember that when the LM9832 is reset (reg08 = 0x20) or in
suspend for longer than a few milliseconds (consult your DRAM
datasheet), DRAM refresh will stop and the Gamma and Coeffi-
cient data may be corrupted.
Some of the CCD signals (RS, CP1, and CP2) can have a small
pulse when line_end occurs. Line_end resets these signals and
depending on how they are programmed to go on and off,
line_end can chop off the signal before its programmed off time.
This is not a problem because the truncation occurs at the end of
every line, after all the image data for that line has been digitized.
Registers 4 and 5 only autowrap to 0 from their highest possible
legal address. If an address higher than the highest legal address
is written, it will continue to increment from the illegal address, not
wrap to 0, and unknown operation may occur. This can not hap-
pen unless the host writes an illegal address to the dataport.
The absolute distance between reference sample and signal
sample must be 2 MCLKs or greater, whether CDS is on or off.
The range of values for the Optical Black (registers 0F and 10),
Reset Pulse (11 and 12), CP1 pulse (13 and 14), CP2 pulse (15
and 16), Reference Sample (17), and Signal Sample (18) settings
depend on the rate of the pixel data coming from the sensor.
16383 pixels x 3 colors. Available horizontal resolutions are
calculated by the optical resolution of the scanner divided by
the HDPI_divider.
Pixel Rate Modes
Line Rate Modes
Mode
stepsize_ITA
Pixel Rate
MCLK/24
MCLK/8
=
stepsize
(Continued)
ITA+1
----------- -
Registers 0F to 18
ITA
Range
0 - 23
0 - 7
38
Always make sure line length (data pixels end - data pixels start)
is >= the horizontal divider. For example, if you are dividing by 12,
the line length must be >=12.
The Line End (registers 20 and 21) setting must be programmed
as follows relative to the Data Pixels End (registers 24 and 25)
setting:
Line End must be >= Data Pixels End + 20
The Data Pixels Start (registers 22 and 23) setting must be >=the
Active Pixels Start (registers 1E and 1F) setting.
The correct Default Phase Difference (registers 51, 52, and 53)
must be set for a scan to restart properly following a pause in the
scanning. See the LM9832 software for information on setting the
DPD register.
The number of fullsteps skipped at the start of a scan may be one
less than the Fullsteps to Skip at Start of Scan (registers 4A and
4B) setting.
The Scanning Step Size (registers 46 and 47) and Fast Feed
Step Size (registers 48 and 49) settings must be > 2.
When reverse is enabled, the LM9832 always stops on Red (line
rate color). When reverse is disabled, it will stop on any color.
The contents of register 01 is not reset by the start of a new scan,
but it is updated to the correct value after the first line has been
scanned. To reset this counter prior to starting a scan, the chip
can be briefly reset (register 7 = 0x20). Since resetting the chip
may have undesired consequences (turning the lamp off briefly,
interrupting DRAM refresh), it is also acceptable to simply wait
until register 01 starts incrementing. At that point the register 01
data will be correct.
Gamma and gain/offset coefficient data should be written with
reg07=0 (idle).
When configured to do so, changes on the Paper Sense and
MISC I/O pins were supposed to generate USB Interrupts. This
functionality is not working at the time of this datasheet’s publica-
tion. The solution (as demonstrated in our Twain Driver software)
is to poll register 02 every 200 to 500ms. This uses very little
additional bandwidth compared to the USB interrupt solution.
Paper Sensor #2 Doesn’t Stop Sensor When Homing: See Sec-
tion 12.16.
www.national.com

Related parts for LM9832CCVJD