AD7734BRUZ Analog Devices Inc, AD7734BRUZ Datasheet - Page 25

no-image

AD7734BRUZ

Manufacturer Part Number
AD7734BRUZ
Description
IC ADC 24BIT 4-CH 28-TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7734BRUZ

Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
24
Sampling Rate (per Second)
15.4k
Number Of Converters
1
Power Dissipation (max)
100mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
24bit
Sampling Rate
15.4kSPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
4.75V To 5.25V
Supply Current
13.5µA
Number Of Elements
1
Resolution
24Bit
Architecture
Delta-Sigma
Sample Rate
3.05MSPS
Input Polarity
Unipolar/Bipolar
Input Type
Voltage
Rated Input Volt
5/10/±5/±10V
Differential Input
No
Power Supply Requirement
Analog and Digital
Single Supply Voltage (typ)
5V
Single Supply Voltage (min)
4.75V
Single Supply Voltage (max)
5.25V
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Power Dissipation
100mW
Integral Nonlinearity Error
±0.0045%FSR
Operating Temp Range
-40C to 105C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
28
Package Type
TSSOP
Input Signal Type
Single-Ended
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7734EBZ - BOARD EVALUATION FOR AD7734
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7734BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7734BRUZ
Manufacturer:
AMI
Quantity:
6 224
Part Number:
AD7734BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7734BRUZ-REEL7
Manufacturer:
ATMEL
Quantity:
12 000
Part Number:
AD7734BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
Continuous Read (Continuous Conversion) Mode
When the Cont RD bit in the mode register is set, the first write
of 48h to the communications register starts the continuous
read mode. As shown in Figure 22, subsequent accesses to the
part sequentially read the channel status and data registers of
the last completed conversion without any further configuration
of the communications register being required.
Note that the continuous conversion bit in the mode register
should be set when entering the continuous read mode.
Note that the continuous read mode is a dump mode reading of
the channel status and data registers regardless of the dump bit
value. Use the channel bits in the channel status register to
check/recognize which channel data is actually being
shifted out.
DOUT
SCLK
RDY
DIN
CS
INTERFACE
INTERFACE
SERIAL
SERIAL
RDY
RDY
REGISTER
CONTINUOUS
CONVERSION
CONTINUOUS
CONVERSION
COMM.
WRITE
38h
START
START
REGISTER
CH0 CONVERSION
CH0 CONVERSION
WRITE
MODE
48h
REGISTER
COMM.
WRITE
48h
Figure 22. Continuous Conversion, CH0 and CH1, Continuous Read
Figure 21. Continuous Conversion, CH0 and CH1, No Data Read
Figure 20. Continuous Conversion, CH0 and CH1, RDYFN = 1
CONVERSION
COMPLETE
CH1 CONVERSION
CH1 CONVERSION
ON CH0
Rev. 0 | Page 25 of 32
STATUS
STATUS
READ
CH0
00h
CH0 CONVERSION
CH0 CONVERSION
READ
DATA
CH0
DATA
00h
Note that the last completed conversion result is being read.
Therefore the RDYFN bit in the I/O port register should be 0,
and reading the result should always start before the next
conversion is completed.
The AD7734 will stay in continuous read mode as long as the
DIN pin is low while the CS pin is low; therefore, write 0 to the
AD7734 while reading in continuous read mode. To exit
continuous read mode, take the DIN pin high for at least 100 ns
after a read is complete. (Write 80h to the AD7734 to exit
continuous reading.)
Taking the DIN pin high does not change the Cont RD bit in
the mode register. Therefore, the next write of 48h starts the
continuous read mode again. To completely stop the continuous
read mode, write to the mode register to clear the Cont RD bit.
READ
DATA
READ
DATA
CH1
CH0
DATA
00h
CONVERSION
COMPLETE
ON CH1
CH1 CONVERSION
CH1 CONVERSION
STATUS
STATUS
READ
00h
CH1
DATA
READ
DATA
CH0 CONVERSION
CH0 CONVERSION
00h
CH0
READ
DATA
CH1
READ
DATA
CH1
DATA
00h
AD7734