Specifications of RD4247MAG3110

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±10g
Interface
I²C
Sensitivity
1mg/bit
Voltage - Supply
1.95 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
MAG3110
Features
LFSTBUSB For Communication To PC, MAG3110FC & MMA8451Q For System Calibration
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Application Sub Type
Magnetic Sensor
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RD4247MAG3110
Manufacturer:
FSL
Quantity:
18
5.1
5.1.1
Data Ready Status
to the OUT_X, OUT_Y, and OUT_Z registers.
Table 10. DR_STATUS Register
ZYXOW is set to 1 whenever new data is acquired before completing the retrieval of the previous set. This event occurs when
the content of at least one data register (i.e. OUT_X, OUT_Y, OUT_Z) has been overwritten. ZYXOW is cleared when the high-
bytes of the data (OUT_X_MSB, OUT_Y_MSB, OUT_Z_MSB) of all active channels are read.
ZOW is set to 1 whenever new Z-axis acquisition is completed before the retrieval of the previous data. When this occurs the
previous data is overwritten. ZOW is cleared any time OUT_Z_MSB register is read.
YOW is set to 1 whenever new Y-axis acquisition is completed before the retrieval of the previous data. When this occurs the
previous data is overwritten. YOW is cleared any time OUT_Y_MSB register is read.
XOW is set to 1 whenever new X-axis acquisition is completed before the retrieval of the previous data. When this occurs the
previous data is overwritten. XOW is cleared any time OUT_X_MSB register is read.
ZYXDR signals that new acquisition for any of the enabled channels is available. ZYXDR is cleared when the high-bytes of the
data (OUT_X_MSB, OUT_Y_MSB, OUT_Z_MSB) of all the enabled channels are read.
ZDR is set to 1 whenever new Z-axis data acquisition is completed. ZDR is cleared any time OUT_Z_MSB register is read.
YDR is set to 1 whenever new Y-axis data acquisition is completed. YDR is cleared any time OUT_Y_MSB register is read.
XDR is set to 1 whenever new X-axis data acquisition is completed. XDR is cleared any time OUT_X_MSB register is read.
Table 11. DR_STATUS Descriptions
11
MAG3110
This read-only status register provides the acquisition status information on a per-sample basis, and reflects real-time updates
ZYXOW
ZYXOW
ZYXDR
Bit 7
ZOW
YOW
XOW
ZDR
YDR
XDR
Sensor Status
DR_STATUS (0x00)
X, Y, Z-axis Data Overwrite. Default value: 0.
0: No data overwrite has occurred.
1: Previous X or Y or Z data was overwritten by new X or Y or Z data before it was completely read.
Z-axis Data Overwrite. Default value: 0.
0: No data overwrite has occurred.
1: Previous Z-axis data was overwritten by new Z-axis data before it was read.
Y-axis Data Overwrite. Default value: 0.
0: No data overwrite has occurred.
1: Previous Y-axis data was overwritten by new Y-axis data before it was read.
X-axis Data Overwrite. Default value: 0
0: No data overwrite has occurred.
1: Previous X-axis data was overwritten by new X-axis data before it was read.
X or Y or Z-axis new Data Ready. Default value: 0.
0: No new set of data ready.
1: New set of data is ready.
Z-axis new Data Available. Default value: 0.
0: No new Z-axis data is ready.
1: New Z-axis data is ready.
Z-axis new Data Available. Default value: 0.
0: No new Y-axis data is ready.
1: New Y-axis data is ready.
Z-axis new Data Available. Default value: 0.
0: No new X-axis data is ready.
1: New X-axis data is ready.
ZOW
Bit 6
YOW
Bit 5
XOW
Bit 4
ZYXDR
Bit 3
Bit 2
ZDR
Bit 1
YDR
Freescale Semiconductor
Bit 0
XDR
Sensors