CS4353-CNZ Cirrus Logic Inc, CS4353-CNZ Datasheet - Page 23

IC DAC STER 106DB 2VRMS 24QFN

CS4353-CNZ

Manufacturer Part Number
CS4353-CNZ
Description
IC DAC STER 106DB 2VRMS 24QFN
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS4353-CNZ

Number Of Converters
1
Package / Case
24-QFN
Number Of Bits
24
Data Interface
Serial
Voltage Supply Source
Single Supply
Power Dissipation (max)
152mW
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Number Of Dac Outputs
2
Resolution
24 bit
Interface Type
Serial
Supply Voltage (max)
3.47 V
Supply Voltage (min)
3.13 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Maximum Power Dissipation
152 mW
Minimum Operating Temperature
- 55 C
Supply Current
10 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1519 - BOARD EVAL FOR CS4353 DAC
Settling Time
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1640

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS4353-CNZ
Manufacturer:
CIRRUS
Quantity:
4 588
Part Number:
CS4353-CNZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
CS4353-CNZ
Quantity:
219
Part Number:
CS4353-CNZR
Manufacturer:
TI
Quantity:
600
Part Number:
CS4353-CNZR
Manufacturer:
CIRRUS
Quantity:
20 000
DS803F1
6. PARAMETER DEFINITIONS
Total Harmonic Distortion + Noise (THD+N)
Dynamic Range
Interchannel Isolation
Interchannel Gain Mismatch
Gain Drift
The ratio of the RMS value of the signal to the RMS sum of all other spectral components over the specified
bandwidth (typically 10 Hz to 20 kHz), including distortion components. Expressed in decibels.
The ratio of the full-scale RMS value of the signal to the RMS sum of all other spectral components over the
specified bandwidth. Dynamic range is a signal-to-noise measurement over the specified bandwidth made
with a -60 dBFS signal. 60 dB is then added to the resulting measurement to refer the measurement to full
scale. This technique ensures that the distortion components are below the noise level and do not affect the
measurement. This measurement technique has been accepted by the Audio Engineering Society, AES17-
1991, and the Electronic Industries Association of Japan, EIAJ CP-307.
A measure of crosstalk between the left and right channels. Measured for each channel at the converter's
output with all zeros to the input under test and a full-scale signal applied to the other channel. Units in deci-
bels.
The gain difference between left and right channels. Units in decibels.
The change in gain value with temperature. Units in ppm/°C.
CS4353
23