9-1393792-7 TE Connectivity, 9-1393792-7 Datasheet - Page 319

Electromechanical Relay DPDT 3A 12VDC 720Ohm Through Hole

9-1393792-7

Manufacturer Part Number
9-1393792-7
Description
Electromechanical Relay DPDT 3A 12VDC 720Ohm Through Hole
Manufacturer
TE Connectivity
Type
Signal Relayr
Datasheets

Specifications of 9-1393792-7

Contact Arrangement
DPDT
Dc Coil Voltage
12 V
Coil Current
16.67 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
2 Form C
Voltage Rating (vdc)
220V
Voltage Rating (vac)
250V
Dropout Volt (min)
0.6VDCV
Coil Resistance
720Ohm
Pick-up Voltage (max)
8.4VDC
Maximum Power Rating
60W/125VA
Operate Time
5ms
Contact Current Rating
3A
Contact Material
AgNi/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
11mm
Product Depth (mm)
10mm
Product Length (mm)
20.2mm
Operating Temp Range
-25C to 85C
Pin Count
8
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
Auxiliary Switches
Various interlock / auxiliary switches are available for the Model 98 contactor.
All auxiliary switches for the Model 98 are snap-on design, no tools required.
Footnotes: Ratings of Auxiliary Interlocks / Switches
(1) Contact Rating Single Circuit NO or NC and two circuit NO/NC:
(2) Contact Rating SPDT (337):
Dimensions are shown for
reference purposes only.
Ordering Information
Standard part numbers listed below are more likely to be available from stock.
3100-30Q9999CY
3100-30T9999CY
Outline Dimensions
1. Series:
2.Packaging:
3.Pole Configuration:
4.Coil Voltage (50/60 Hz.):
5.Contact Ratings (Inductive):
6.Customer ID Suffix:
7. Option Code:
3100 = 3-pole, 20-40 FLA contactor
Y = Individual Pack
- = Bulk Pack
A-ZZZ = Customer specific information (assigned by factory)
30 = 3 Form X (3PST-NO-DM)
Q = 24VAC
T = 120VAC
7 = 20 FLA
999 = Standard Model
Leave Blank = No customer-specific options
Amperes - Break
Amperes - Make
Amperes - Continuous
10A, 1/3 HP , 125 or 250 VAC
1/2A, 125 VDC; 1/4A, 250 VDC:
4A 120 VAC on Lamp Load
ONE SPDT
2.0 MAX.
PER SIDE
SWITCH
(50.8)
Shown with Optional Auxiliary Switches
(76.2)
3.00
U = 208/240VAC
V = 277VAC
8 = 25 FLA
3100-30U9999CY
3100-30Q10999CG
120V
3.0
30
10
(86.1)
2.39
TWO SPDT
SWITCHES
240V
000-998 = Factory assigned customer ID
PER SIDE
1.5
15
10
Typical Part No.
(45.21)
H = 480VAC
1.78
I = 24VAC, molded
480V
0.75
9 = 30 FLA
7.5
10
(75.44) 1.19
2.97
Dimensions are in inches over
(millimeters) unless otherwise
specified.
3100-30T10999CG
3100-30U10999CG
600V
0.6
10
6
(30.23)
B
10 = 40 FLA
1 N/O / 1 N/C
.203 TYP.
(5.156)
.455 DIA.
J = 120VAC, molded
K = 208/240VAC, molded
(11.56)
.250 TYP.
(6.35)
A - ZZ = Factory assigned customer-specific options.
3100
.203 TYP.
(5.156)
Catalog 1308242
Issued 3-03
2.375 TYP.
(60.325)
(50.8)
2.00
Specifications and availability
subject to change.
Equipped with 0.250” (6.35) Quick Connect Terminals
Equipped with #6-32 Screw Terminals & Saddle Clamps
Description
Single unit interlock
configurations listed.
Maximum of two.
(One on each side.)
See footnote (1) for ratings.
Description
Single unit interlock
configurations listed.
Maximum of two.
(One on each side.)
See footnote (1) for ratings.
SPDT Circuit
(Either one or two
switches per side.)
See footnote (2) for ratings.
SPDT Dry Circuit
0.1 amp max.
Gold Flashed Contacts
(3.175)
-
.125
M = 277VAC, molded
W = 480VAC, molded
(82.55)
3.25
(95.25)
3.75
30
Factory Modifications
Factory Modifications
Termination Options
#10-32 Combination
ORDERING NOTE: “Standard” terminals need not be specified
in the “Ordering Information” chart above. “Special” terminals
are offered on a special order basis. Special order items may be
subject to extended leadtimes and significant minimum order
quantities. Your Tyco Electronics sales engineer must consult
with the factory before providing price and availability
information regarding items with these options.
20, 25, 30, 35 FLA
Phillips, Slotted &
5/16 Hex Head
Standard on
#12 Washer
Q
Contact Config.
Contact Config.
NO
NO
1
0
1
2
0
2
1
0
1
2
0
2
1
2
2
4
1
2
4
NC
NC
0
1
1
0
2
2
0
1
1
0
2
2
1
2
2
4
1
2
4
9
20, 25, 30, 35 FLA
with Pressure
#10-32 Sems
PRODUCTS UNLIMITED
Special on
Kit Catalog
Screw
Kit Catalog
98220-303
98220-331
98220-332
98220-303
98220-331
98220-332
98220-303
98220-331
98220-332
98220-303
98220-331
98220-332
98220-337
98220-338
98220-337
98220-338
98220-341
98220-340
98220-340
Plate
Number
Number
999
Field Added Kits
Field Added Kits
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Lug accepts 14-4
Kits Required
Kits Required
Number of
Number of
Cu/Al AWG
on 40 FLA
Standard
1
1
1
2
2
2
1
1
1
2
2
2
1
1
2
2
1
1
2
(6.43)
.253