EMC2103-2-AP-TR Standard Microsystems (SMSC), EMC2103-2-AP-TR Datasheet - Page 28

no-image

EMC2103-2-AP-TR

Manufacturer Part Number
EMC2103-2-AP-TR
Description
CLOSED LOOP RPM FAN CONTROLLER
Manufacturer
Standard Microsystems (SMSC)
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EMC2103-2-AP-TR
Manufacturer:
SMSC
Quantity:
20 000
Revision 0.88 (06-30-08)
5.5.1
M a in ta in F a n D rive
Programming the RPM Based Fan Speed Control Algorithm
The RPM based Fan Speed Control Algorithm powers-up disabled. The following registers control the
algorithm. The EMC2103 fan control registers are pre-loaded with defaults that will work for a wide
variety of fans so only the TACH Target Register is required to set a fan speed. The other fan control
registers can be used to fine-tune the algorithm behavior based on application requirements.
Note that steps 1 - 7 are optional and need only be performed if the default settings do not provide
the desired fan response.
1. Set the Valid TACH Count Register to maximum number of tach counts to indicate the fan is
2. Set the Spin Up Configuration Register to the Spin Up Level and Spin Time desired.
spinning.
R e d u ce F a n D riv e
Figure 5.4 RPM based Fan Speed Control Algorithm
Y e s
Y e s
M e a su re F a n S p e e d
S e t T A C H T a rg e t
N o
R e a d in g =
R e a d in g <
R e q u ire d
S p in U p
T a rg e t?
T a rg e t?
C o u n t
T A C H
T A C H
T A C H
T A C H
?
DATASHEET
N o
In cre a s e F a n D rive
28
Y e s
N o
RPM-Based Fan Controller with HW Thermal Shutdown
P e rfo rm S p in U p
R o u tin e
R a m p R a te C o n tro l
SMSC EMC2103
Datasheet

Related parts for EMC2103-2-AP-TR