SDV-DM7 AC200/220 Omron, SDV-DM7 AC200/220 Datasheet - Page 94

no-image

SDV-DM7 AC200/220

Manufacturer Part Number
SDV-DM7 AC200/220
Description
Sensor Hardware & Accessories VOLTAGE SENSOR
Manufacturer
Omron
Datasheets

Specifications of SDV-DM7 AC200/220

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Precautions
Approximately 0.5 s is required for operation. When confirming the
operating value, gradually change the input voltage while checking
the value.
Power supply voltage fluctuations and the ambient operating temper-
ature must be maintained within the allowable ranges. Be particularly
careful not to apply an overvoltage beyond the specified range for
the voltage detection.
Do not use the SDV in locations subject to corrosive or explosive
gases.
The SDV cannot be used to detect momentary power interruptions
because of its response time. Use the S87A to detect momentary
power interruptions.
An SDV cannot be used with a circuit containing thyristors, or VVVF
inverters, because these elements can change the output waveform
to the point that the SDV will malfunction.
Mounting
When mounting with the PL08 or PL15 Back Connection Socket,
insert the Socket into a 1- to 4-mm panel from the back and secure it
with screws. Do not mount the SDV until the Socket has been
mounted firmly. Be sure that the key groove on the Socket is
mounted on the bottom, and also secure the SDV to the panel with
screws.
When mounting with the 8PFA or 14PFA Back Connection Socket,
insert the SDV into the Socket and secure it with the hooks. Leave
approximately 30 mm or more between Sockets to allow enough
space for the hooks.
When mounting more than one SDV, allow at least 30 mm or more
between them.
92
Cat. No. N036-E1-05
Voltage Sensor
S87A Power Interruption Detector
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
SDV

Related parts for SDV-DM7 AC200/220