MPC603RRX266TC Freescale Semiconductor, MPC603RRX266TC Datasheet - Page 23

no-image

MPC603RRX266TC

Manufacturer Part Number
MPC603RRX266TC
Description
IC MPU 32BIT 266MHZ 255-CBGA
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MPC603RRX266TC

Processor Type
MPC603e PowerPC 32-Bit
Speed
266MHz
Voltage
2.5V
Mounting Type
Surface Mount
Package / Case
255-CBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC603RRX266TC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
PLL_CFG[0:3]
1.8 System Design Information
This section provides electrical and thermal design recommendations for successful application of the 603e.
1.8.1 PLL ConÞguration
The 603e PLL is conÞgured by the PLL_CFG[0Ð3] signals. For a given SYSCLK (bus) frequency, the PLL
conÞguration signals set the internal CPU and VCO frequency of operation. The PLL conÞguration for the
PID7t-603e is shown in Table 12 for nominal frequencies.
Notes:
1. Some PLL configurations may select bus, CPU, or VCO frequencies which are not supported; see
2. In PLL-bypass mode, the SYSCLK input signal clocks the internal processor directly, the PLL is disabled, and
0100
0101
0110
1000
1110
1010
0111
1011
1001
1101
0011
1111
3. In clock-off mode, no clocking occurs inside the 603e regardless of the SYSCLK input.
4. 80 MHz operation is not supported for the PBGA package (see Table 7)
Section 1.4.2.1, “Clock AC Specifications,” for valid SYSCLK and VCO frequencies.
the bus mode is set for 1:1 mode operation. This mode is intended for factory use only.
Note: The AC timing specifications given in this document do not apply in PLL-bypass mode.
2x
2x
2.5x
3x
3.5x
4x
4.5x
5x
5.5x
6x
Bus-to-Core
Multiplier
Freescale Semiconductor, Inc.
For More Information On This Product,
2x
4x
2x
2x
2x
2x
2x
2x
2x
2x
Multiplier
Core-to
PID7t-603e Hardware Specifications
VCO
CPU Frequency in MHz (VCO Frequency in MHz)
Table 12. PLL Configuration
Go to: www.freescale.com
150
(300)
25 MHz
Bus
150
(300)
166
(333)
183 (366)
200
(400)
33.33 MHz
Bus
PLL bypass
Clock off
40 MHz
80
(320)
160
(320)
180
(360)
200
(400)
220
(440)
240
(480)
Bus
4
50 MHz
100
(400)
150
(300)
175
(350)
200
(400)
225
(450)
250
(500)
275
(550)
300
(600)
Bus
System Design Information
60 MHz
120
(480)
150
(300)
180
(360)
210
(420)
240
(480)
270
(540)
300
(600)
Bus
66.67 MHz
133
(532)
166
(333)
200
(400)
233 (466)
267 (533)
300 (600)
Bus
75 MHz
150
(300)
150
(600)
187
(375)
225
(450)
263
(525)
300
(600)
Bus
23

Related parts for MPC603RRX266TC