K2CU-F80A-C AC32-80A AC100 Omron, K2CU-F80A-C AC32-80A AC100 Datasheet - Page 4

no-image

K2CU-F80A-C AC32-80A AC100

Manufacturer Part Number
K2CU-F80A-C AC32-80A AC100
Description
Detector Switches Heater Fault Detector
Manufacturer
Omron
Datasheet

Specifications of K2CU-F80A-C AC32-80A AC100

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
K2CU
K2CU-F Series
When power is supplied to the heater (when the contactor is ON), a
current flows through the wires to the heater elements. At the same
time, a voltage is imposed on the power circuit of the K2CU-F.
The current flowing to the heater wires is detected by the detector
sections through each Current Transformer (CT) incorporated by
the K2CU-F.
The current signals transmitted by the two CTs are sent to the cur-
rent-voltage converters, smoothing circuits, and comparators as
shown in the diagram.
K2CU-P Series
The K2CU-P operates basically in the same way as the K2CU-F.
The comparator compares external current signals and the refer-
ence value and outputs the result of the comparison to the output
circuit.
4
Heater elements
Power source
Heater elements
Power source
CT
2
Contactor
CT
1
Contactor
Current-
voltage
converter
Current-
voltage
converter
Note: The dotted lines indicate the line conductors passing through the windows of the current transformers.
1
2
CT
Current-
voltage
converter
Smoothing
circuit
Smoothing
circuit
Smoothing
circuit
Comparator
Comparator
Setting
circuit
Setting
circuit
The signal generated by the reference voltage generator is sent to
the setting circuit to provide a reference value. The reference value
is sent to the comparators. Each comparator compares its heater
element current input and the reference value. If the input is lower
than the reference value, a signal is sent to the output circuit.
There are two detector sections operating independently. If either of
the input signals from the CTs is lower than the reference value, the
output relay and alarm indicator will be activated.
The K2CU-F incorporates a voltage fluctuation compensation func-
tion which automatically corrects the reference value if the supply
voltage fluctuates.
Comparator
Reference
voltage
generator
Reference
voltage
generator
Output
circuit
To each circuit
To each circuit
Output relay
Power
circuit
Output
circuit
Power
circuit
Alarm indicator
X
200/220 V
Output relay
X/c
S1
X
6
CM1
Alarm indicator
S2
b1
a1
100/110 V
7
Buzzer
X/c
BZ
8
5
4
3
0 V
K2CU
Buzzer
BZ

Related parts for K2CU-F80A-C AC32-80A AC100