Page 1
... Un-shielded (See Note.) 2 dia. 3.5 dia. Shielded 3.8 dia. M5 5.4 dia. M8 Note: The E2C-CR5B2 with shielded construction cannot be embedded in metal. J AMPLIFIER UNIT Item Amplifier Amplifier with built-in connection (for CompoBus/S) E2C-T11 Sensing distance All temperature ranges 0°C to 40°C (32°F to 104°F) ...
Page 2
... E2C operation - - even if teaching is successful. 2. The above distances for teaching without a target object were measured without surrounding metal or background. 3. E2C-T16 can only be used with CompoBus/S system. 2 Sensor head E2C-CR5B2 E2C-CR8A E2C-X1A E2C-CR8B E2C-C1A VDC ± 10% (operation 26.4 VDC), ripple (p-p): ±10% max. ...
Page 3
... E2C-T J E2C-j SENSOR HEADS Item Sensor head Item E2C-CR5B2 Target object Ferrous metal (Refer to Engineering Data for non-ferrous metal as target objects) Standard target object Iron Stable sensing range (within whole 0 to 0.5 mm rated temperature range 0.02 in) Stable sensing range at 0°C to 40° ...
Page 4
... Approx Setting ON Control output OFF ON Output indicator (orange) OFF ON STB (stability) indicator (green) OFF NC Setting ON Control output OFF ON Output indicator (orange) OFF ON STB (stability) indicator (green) OFF 4 Brown VDC Black NPN open collector output Blue 0 V Load 100 mA max. Time E2C-T ...
Page 5
... Sensing distance Approx. 93% of sensing distance Sensor Connection Terminal (shielded ground) Sensor Connection Terminal (conductor) TEACH Button Applicable Sensor Head Cable Length Selector E2C-CR5B2 Cable Length Compensator Set this switch according to the E2C-CR8A cable length as shown in the table E2C-CR8B below. E2C-X1A E2C-C1A ...
Page 6
... E2C-X1A/-C1A Target object: iron Sensing distance (variable): 0 E2C-X1A Sensing Head E2C-C1A Sensing Head Y (mm) J SENSING DISTANCE VS. TARGET OBJECT SIZE AND MATERIAL (TYPICAL) E2C-CR5B2 Iron Side of target object ℓ (mm) 6 E2C-CR8j Target object: iron Sensing distance (variable): 0.16 to 0.8 mm E2C-CR8j Sensing Head ...
Page 7
... Two, 3.2-dia mounting holes 4.4 3.4 (0.17) (0.13) Two, mounting holes 33.4 16 (1.31) (0.63) E2C-T Iron Brass Aluminum 7 (0.28) 6 (0.24) Vinyl-insulated round cable with 4 dia., three cores (0.12 dia. x 18) Standard length Mounting Holes Two, M3 10.6 (0.42) 2 ...
Page 8
... E2C-T E2C-T16 10 (0.39) 4 (0.16) 2 (0.08) R2 21.8 (0.86) J SENSOR HEADS E2C-CR5B2 15 (0.59) 2 dia. E2C-CR8A E2C-CR8B 3.5 dia. 15 (0.59) 2.5-dia. coaxial cable Standard length Note: 3.8-dia. coaxial cable is used for the E2C-CR8B. E2C-X1A 18 8 (0.71) (0.31) 15 (0.59) 4 (0.16) E2C-C1A 5.4 (0.21) 18 (0.71) 2.5-dia. coaxial cable ...
Page 9
... Note: 1. Refer to details in the Sensitivity Setting (Automatic Teaching) section of this data sheet. 2. Before use, be sure to perform the teaching of the E2C- fine-difference teaching is performed, reset failures may result when the E2C operation even if the teaching is suc- cessful. Make sure that the E2C-T resets smoothly after the teaching. ...
Page 10
... Check the connection of the sensor cable and change the position of the target object and the set distance. Then repeat steps 3 through 6. Note: Be sure to perform the teaching of the E2C-T before use. Once the teaching of the E2C-T is performed, the teaching data set in the E2C-T will be retained even after turning OFF the E2C-T. ...
Page 11
... E2C-T without a mistake in polarity. Brown Load Sensor Black (Load short-circuiting) Blue J MOUNTING Do not tighten the nut of the E2C-j excessively. Tighten the nut with a toothed washer to the following torque. Part number Torque E2C-X1A 0. (10 kgf S cm) E2C-X1R5A 2 (20 kgf S cm) Note: The above applies to a nut used with a toothed washer. ...
Page 12
... Sensors, and the specified ratings may not be satisfied in all permissible temperature or sensing distance ranges. Test the operation of the Sensors before using them in an actual application. Note: The cable length of E2C-CR5B2 cannot be adjusted, so mutual interference cannot be manipulated for this sensor using cable length selector settings ...