SA56004HDP-T NXP Semiconductors, SA56004HDP-T Datasheet - Page 7

Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 1OC TS

SA56004HDP-T

Manufacturer Part Number
SA56004HDP-T
Description
Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 1OC TS
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004HDP-T

Full Temp Accuracy
+/- 1 C, +/- 3 C
Package / Case
SOT-505
Digital Output - Bus Interface
I2C
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SA56004HDP,118
NXP Semiconductors
SA56004X_5
Product data sheet
7.5 Starting conversion
7.6 Low power software standby mode
7.7 Temperature data format
Upon POR, the RUN/STOP bit 6 of the configuration register is zero (default condition),
then, the device will enter into its free-running operation mode in which the device A/D
converter is enabled and the measurement function is activated. In this mode, the device
cycles the measurements of the local and remote temperature automatically and
periodically. The conversion rate is defined by the programmable conversion rate stored in
the conversion rate register. It also performs comparison between readings and limits of
the temperature in order to set the flags and interruption accordingly at the end of every
conversion. Measured values are stored in the temp registers, results of the limit
comparisons are reflected by the status of the flag bits in the status register and the
interruption is reflected by the logical level of the ALERT and T_CRIT output. If the
power-on temperature limit is not suitable, the temp limit values could be written into the
limit registers during the busy-conversion duration of about 38 ms of the first conversion
after power-up. Otherwise, the status register must be read and the configuration bit 7
must be reset in order to recover the device from interruption caused by the undesired
temp limits.
The device can be placed in a software standby mode by setting the RUN/STOP bit 6 in
the configuration register HIGH (logic 1). In standby, the free-running oscillator is stopped,
the supply current is less than 10 A if there is no SMBus activity, all data in the registers
is retained. However, the SMBus is still active and reading and writing registers can still be
performed. A one-shot command will initiate a single conversion which has the same
effect as any conversion that occurs when the device is in its free-running mode. To
restore the device to free running mode, set the RUN/STOP bit 6 LOW (logic 0).
The temperature data can only be read from the Local and Remote Temperature
registers; the setpoint registers (e.g., T_CRIT, LOW, HIGH) are read/write.
Both local and remote temperature reading data is represented by an 11-bit,
2’s complement word with the Least Significant Bit (LSB) = 0.125 C. The temperature
setpoint data for the remote channel is also represented by an 11-bit, 2’s complement
word with the LSB = 0.125 C. The temperature setpoint data for both the local channel
and the T_CRIT setpoints are represented by 8-bit, 2’s complement words with the
LSB =1.0 C. For 11-bit temp data, the data format is a left justified, 16-bit word available
in two 8-bit registers (high byte and low byte). For 8-bit temp data, the data is available in
a single 8-bit register (high byte only).
8. Local LOW setpoint (LLS) and Remote LOW temperature setpoints (RLSHB) at 0 C.
9. Conversion Rate register (CR) is set to 8h; the default value of about 16
conversions/s.
Rev. 05 — 22 May 2008
Digital temperature sensor with overtemperature alarms
SA56004X
© NXP B.V. 2008. All rights reserved.
7 of 36

Related parts for SA56004HDP-T