Z8023010VSC Zilog, Z8023010VSC Datasheet - Page 105

IC 10MHZ Z8000 CMOS ESCC 44-PLCC

Z8023010VSC

Manufacturer Part Number
Z8023010VSC
Description
IC 10MHZ Z8000 CMOS ESCC 44-PLCC
Manufacturer
Zilog
Series
IUSC™r
Datasheet

Specifications of Z8023010VSC

Controller Type
Serial Communications Controller (SCC)
Interface
Bus
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
4mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
44-LCC (J-Lead)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8023010VSC
Manufacturer:
ZILOG
Quantity:
1 831
Part Number:
Z8023010VSC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8023010VSC00TR
Manufacturer:
Zilog
Quantity:
10 000
PS005308-0609
IUS Problem Solutions
The following methods can be used to work around the previously described problems.
When the SDLC FIFO is enabled and Receive Interrupts on Special Conditions Only is
selected, software checks that there is a Receive Character Available interrupt, which is
generated by DMA reading an EOF character, and before issuing the
IUS
The processor does not acknowledge this interrupt because it is servicing another
interrupt.
The processor finishes servicing the other interrupt and uses the
command.
The IP bit reset corresponding to the EOF, and the EOF interrupt is lost.
Alternate Operating Mode–A similar operating mode can be used to achieve the same
functionality with minimum code modifications. The ESCC must operate in Receive
Interrupts on First Character and Special Condition, instead of Receive Interrupt on
Special Condition Only.
In this mode, the Anti-Lock feature is not enabled. The FIFO is locked after the last
character of a frame has been transferred, and the interrupt condition does not
disappear until after an
Highest IUS
Daisy Chain– This workaround uses the following two conditions:
If both conditions are satisfied, allowing nested interrupts can solve the problem.
The processor servicing an interrupt on the daisy chain must be interruptible again
from another interrupt of higher priority on that same daisy chain.
RR7 Register–This workaround is applicable if the EOF interrupt is used only to
notify another part of the software that there has been another frame received:
command. Otherwise, the EOF interrupt conditions are cleared by that command.
The EOF interrupt is the highest priority interrupt if only one channel is used.
Channel A is the only channel issuing interrupts.
Read RR7 after issuing the
Check bit 6 of RR7. This bit, when set, indicates that the SDLC frame FIFO con-
tains a valid frame. Although one interrupt might have been lost (IP reset) by the
Reset IUS
available in the frame FIFO. If bit 6 of RR7 is 1, notify the concerned part of the
software that at least one frame is available in the frame FIFO.
command can clear any IP bit.
command, bit 6 of RR7 always indicates that at least one frame is
Error Reset
Reset IUS
command is issued to the ESCC. No
command.
Product Specification
Z80230/Z85230/L Errata
Reset Highest IUS
Reset Highest
Reset
100

Related parts for Z8023010VSC