VQ1301N-51 SMC Corporation, VQ1301N-51 Datasheet - Page 27

no-image

VQ1301N-51

Manufacturer Part Number
VQ1301N-51
Description
SOLENOID VALVE, BASE MT, 5 PORT, PLUG-IN TYPE, 24VDC, 3 POSITION CLOSED CENTER
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1301N-51

Brand/series
VQ Series
Configuration
3-Position Closed Center
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Number Of Ports
5
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 3 Position Closed Center Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
How to Order Valves
Type of actuation
b
Connector
terminal no.
A
B
C
1
2
3
4
5
Electrical Wiring Specifications
Flat ribbon cable connector
1
2
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.C.)
4-position dual port (N.C. +N.O.)
3-position pressure center
3-position exhaust center
VQ
3-position closed center
VQ1000
VQ2000
Series
20
18
16
14
12
10
8
6
4
2
2-position double
2-position single
19
17
15
13
11
9
7
5
3
1
1
Triangle
mark
indicator
position
0
1
1
Rubber seal
Metal seal
Seal
0
Station 1
Station 2
Station 3
Station 4
Station 5
Station 6
Station 7
Station 8
0
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
COM.
COM.
Symbol
K
N
R
Function
Nil
Terminal no.
Note 1)
Note 2)
Note 2)
B
20
18
16
14
12
10
19
17
15
13
11
8
6
9
7
5
4
3
2
1
response type
Specifications
High-pressure type
Standard
Negative
(1.0 MPa)
common
High-speed
External
COM spec.
Base Mounted
pilot
Positive
5
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(+)
(+)
Light/surge voltage suppressor
Nil
E
Manual override
(0.4 W)
(0.95 W)
(0.95 W)
Nil
B
C
D
Polarity
DC
COM spec.
Non-locking push type (Tool required)
Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)
Positive
None
Yes
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(–)
(–)
Note 1) Metal seal only
Note 2) Refer to “Semi-standard” on pages 56 to
Note 3) When two or more symbols are specified,
Note)
1
57 for external pilot and negative common
specifications.
indicate them alphabetically. Combination
of [B] and [K] is not possible.
Plug-in Unit
Coil voltage
5
Nil
Q
CE compliant
As the standard electrical wiring specifications, double wiring
(connected to SOL. A and SOL. B) is adopted for the internal wiring
of each station for 8 stations or less, regardless of valve and option
types.
Mixed single and double wiring is available as semi-standard. Refer
to “Semi-standard” on page 56 for details.
CE compliant
24 VDC
Note) When using the negative common specifications, use
Series
valves for negative common. (Refer to page 56,)
Refer to “Semi-standard” on page 56 for details.
Specify the part numbers for valves and options
together beneath the manifold base part number.
<Example>
Flat ribbon cable kit with cable (3 m)
How to Order Manifold Assembly
VV5Q11-08C6JU2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
Prefix the asterisk to
the part nos. of the
solenoid valve, etc.
VQ1000/2000
1 set–Manifold base part no.
2 sets–Valve part no. (Stations 1 to 2)
4 sets–Valve part no. (Stations 3 to 6)
1 set–Valve part no. (Station 7)
1 set–Blanking plate part no. (Station 8)
Write sequentially from the
1st station on the D-side.
When part nos. written col-
lectively are complicated,
specify them by means of the
manifold specification sheet.
26