VQ1301N-51 SMC Corporation, VQ1301N-51 Datasheet - Page 34

no-image

VQ1301N-51

Manufacturer Part Number
VQ1301N-51
Description
SOLENOID VALVE, BASE MT, 5 PORT, PLUG-IN TYPE, 24VDC, 3 POSITION CLOSED CENTER
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1301N-51

Brand/series
VQ Series
Configuration
3-Position Closed Center
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Number Of Ports
5
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 3 Position Closed Center Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
Manifold Specifications
How to Order Manifold
33
b
b
b
1
2
1
VV5Q
This kit has a small terminal block inside a junction box.
Maximum stations: 24 (VQ1000), 20 (VQ2000)
Open the terminal block cover to connect
the wires to the terminal block.
Step 1. Removing the terminal block cover
Loosen the screws on the terminal block cover and open
it in the direction shown by the arrow. The cover can
then be removed from the terminal block.
T
Enclosure: Dust-tight, Water-jet-proof (IP65) compatible
Step 3. Mounting the
Hook groove (a) on shaft (b) and close
the cover. Then tighten the screws.
The electrical entry port {VQ1000: G 1/2, VQ2000: G 3/4}
permits connection of conduit fittings.
(Series VQ2000)
VQ1000
VQ2000
IP65 compliant
Series
3.5
Note 1) VQ2000: Max. 20
Note 2) Refer to page 56 for
Note) For negative common
24
VQ1000
VQ2000
Series
02
Plug-in unit
Note)
Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.
Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
Note 5) Inch-size one-touch fittings are available. Refer to “Semi-standard” on page 57 for details.
specifications, refer to
“Semi-standard” on page 56.
terminal block cover
Manifold
stations
details.
Series
kit (Terminal block box)
direction
Stations
24 stations
1
Example) B6 (Bottom ported elbow with ø6 one-touch fitting)
double check block (direct mounting), enter “MM” and give instructions in the manifold
specification sheet.
Piping
2 stations
Side
Side
1
Piping specifications
1(P), 3(R)
C10
VQ1000/2000
C8
08 C6
Terminal Block Connection (VQ1000)
Symbol
CM
MM
M2.5
Cylinder port
M5
C3
C4
C6
C8
Step 2. Wiring
The diagram on the left shows the terminal block
wiring schematic. All stations are provided with
double solenoid wiring. Insert each lead wire into the
terminal opening and tighten the screw directly
above.
How to connect is inserting the lead wire into the
terminal window, then
the top. (Tightening
Port size
Note 3)
Note 4)
C3,C4,C6,M5
Mixed sizes and with port plug
Mixed size for different types of piping, option installed
4(A), 2(B)
C4,C6,C8
With ø3.2 one-touch fitting
With ø4 one-touch fitting
With ø6 one-touch fitting
With ø8 one-touch fitting
T
(a)
M5 thread
Port size
0
(b)
Max. 24 stations
Max. 20 stations
Applicable
stations
torque: 0.25 to 0.35 N·m)
tighten the screw on
CE compliant
DC specification only
VV5Q11
Nil
Q
VQ1000 VQ2000
Cover
CE compliant
b
Symbol
B
D„
K
R
G1
G2
G3
J„
b
Option
D0
Nil
Note 2)
Note 7)
W
Note 6)
The quantity of terminal blocks used depends
on the number of manifold stations:
As the standard electrical wir-
ing specifications, double wir-
ing (connected to SOL. A and
SOL. B) is adopted for the in-
ternal wiring of each station for
12 stations or less, regardless
of valve and option types.
Mixed single and double wiring
is available as semi-standard.
Refer to page 56 for details.
Note) When using the negative common specifications,
D
N
S
Electrical entry
Electrical Wiring Specifications: VQ1000
Note 4)
Note 4)
Note 4)
Note 5)
Note 6)
Note 1) When two or more symbols are specified, indicate them alphabetically.
Note 2) Models with a suffix “-B” have check valves for prevention of back
Note 3) The number of stations that may be displayed is longer than the mani-
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of “J”
Note 6) Specify the wiring specifications by means of the manifold specification sheet.
Note 7) Indicate “R” for the valve with external pilot.
9 to 12 stations
2 to 8 stations
G 1/2
1st row
use valves for negative common.
Refer to “Semi-standard” on page 56 for details.
Manifold
DIN rail length specified („: Stations 02 to 24)
Special wiring spec. (Except double wiring)
Enclosure: Dust-tight, Water-jet-proof (IP65)
With DIN rail bracket (Without DIN rail)
Direct EXH outlet with built-in silencer
Example) -BRS
pressure at all manifold stations. When a back pressure check valve
is desired, and is to be installed only in certain manifold stations, spec-
ify the mounting position by means of the manifold specification sheet.
fold number of stations.
and “N” is not available.
With back pressure check valve
--
2nd row
2 sets of regulator unit
3 sets of regulator unit
1 set of regulator unit
Terminal block
DIN rail mounting
-------
With ejector unit
With name plate
2 rows
3 rows
External pilot
3rd row
Option
None
Station 10
Station 11
Station 12
Station 1
Station 2
Station 3
Station 4
Station 5
Station 6
Station 7
Station 8
Station 9
Electrical entry
2 x G 3/4
COM.
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
COM.
The total number of
stations is tabulated
starting from station
one on the D-side.
Terminal no.
VV5Q21
VQ1000 VQ2000
COM
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
11A
11B
12A
12B
COM
COM spec.
Positive
(+)
(+)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
COM spec.
Polarity
Negative
(–)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(–)
Note)

Related parts for VQ1301N-51