F3SJ-A0305P20 Sti (Scientific Technologies, Inc.), F3SJ-A0305P20 Datasheet

no-image

F3SJ-A0305P20

Manufacturer Part Number
F3SJ-A0305P20
Description
Safety Light Curtain, 20mm Resolution, 305 mm Protected Height (Order Cables Sep
Manufacturer
Sti (Scientific Technologies, Inc.)
Type
Light Curtainr
Datasheet

Specifications of F3SJ-A0305P20

Primary Type
Photoelectric
Resolution
20 mm (0.79 In.), 30 mm (1.18 In.)
Protected Heights
20 mm and 30 mm Protected Heights From 245 to 2495 mm (9.6 to 98 In.)
Detection Capability
20 mm Diameter
Beam Gap
15 mm
Operating Range
0.2-9 m
Lead Free Status / Rohs Status
RoHS Compliant part
D
F3SJ-A
F3SJ-A
Safety Light Curtain
n
n
n
n
D6
Resolution: 14 mm (0.55 in.),
20 mm (0.79 in.), 30 mm
(1.18 in.), or 55 mm (2.17 in.)
Range: 7 m (23 ft.) or 9 m
(29.5 ft.) dependent on
minimum object resolution and
protected height
Protected heights: 14 mm pro-
tected heights from 245 to 1631
mm (9.6 to 64 in.), 20 mm and
30 mm protected heights from
245 to 2495 mm (9.6 to 98 in.),
55 mm from 270 to 2470 mm
(10.6 to 97 in.)
Very compact size – 30 x 24 mm
(1.18 x 0.94 in.)
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
n
n
n
n
n
n
n
n
n
n
n
Cascaded designs possible –
4 segments, up to 400 beams
Warning zone function
Partial muting
Position detection muting
Fixed blanking
Floating blanking – up to four
beams
External Device Monitoring
Two PNP safety outputs
One NPN auxiliary output
Cross-talk prevention
Range selection
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
Options
n
n
n
n
n
n
n
featured safety light curtain that
meets demanding and complex
guarding requirements.
F3SJ-A combines several features
which allow it to be used in a
variety of ways. These features in-
clude a warning zone function, as
well as fixed and floating blank-
ing. Also included is a valuable
feature known as “partial muting”.
Device Monitoring (EDM) is
included and cross-talk preven-
tion features are standard.
be configured by using either a
handheld setting console or by
connecting to a computer running
the convenient and comprehen-
sive SD Manager programming
software.
Handheld setting console
SD manager programming
software
F3SP/F3SX Safety Controller
Weld shields
IP67 enclosures
Multiple mounting options
Description
The F3SJ-A system is a full-
Inside its compact housing the
For complete safety, External
For ease of use, the F3SJ-A can
C
R
US
A
Go to the Engineering Guide
For in-depth information on
safety standards and use.

Related parts for F3SJ-A0305P20

F3SJ-A0305P20 Summary of contents

Page 1

... For complete safety, External Device Monitoring (EDM) is included and cross-talk preven- tion features are standard. For ease of use, the F3SJ-A can be configured by using either a handheld setting console or by connecting to a computer running the convenient and comprehen- sive SD Manager programming software ...

Page 2

... If the person then enters the danger zone the F3SJ-A will send a stop signal to the guarded machine. In addition, the auxiliary output can be used to activate a flashing lamp to alert the person in the warning zone. ...

Page 3

... F3SJ-A Description (continued) n Programming Options Using the SD Manager software, all features of the F3SJ-A can be set and checked. Features include: D Display of system specifications: n Model – Number of beams – Minimum object resolution – Response time – Settings for: n Fixed blanking – Floating blanking – ...

Page 4

... Dedicated controller multi-input Safety circuit configuration When an emergency stop or door switch is used in conjunction with the F3SJ-A, the safety circuit becomes more complex. The F3SX safety controller is one possible solution. Four models are available to match your desired inputs and outputs. Use an F39-CN5 branch connector to significantly reduce the time required to make the proper connections ...

Page 5

... F3SJ-A Wiring n Wiring for Single F3SJ-A Application Detection of a welded relay contact is possible without a controller relay unit. D Emitter F39-JC@A-L KM3 +24 VDC Light incident Light interrupted External test switch (S1) Reset switch (S2) Control output KM1,KM2 N.O. contact KM1,KM2 N.C. contact PLC input (See note.) PLC output OmrOn Scientific technOlOgieS, inc ...

Page 6

... This example shows the connection when auxiliary 34 output the standard setting (ON when light is KM2 interrupted). 3. When the F3SJ-A is series- connected more sets are connected to the total system of the F3SX, power must be supplied to the F3SJ-A from external source. For details, see the F3SX installation manual. ...

Page 7

... PLC, etc. Motor controller (operation command) OFF-delay time For the Latest Information Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca F3SJ-A settings • Auto reset mode • External device monitoring function disabled G9XS-AD322-T15 settings • Auto reset mode • Using feedback loop S34 ...

Page 8

... X, Y and Z directions 2 conformity/Approvals Approvals: All F3SJ-A systems have been EC type examined to the requirements of IEC 61496-1, -2 for a Type 4 ESPE conforming to Standards: ANSI/RIA R15.06-1999; ANSI B11.19-2003; OSHA 1910.217(c); OSHA 1910.212.A Specifications are subject to change without notice. OmrOn Scientific technOlOgieS, inc. ...

Page 9

... F3SJ-A Specifications (continued) n Control Unit Power Supply Voltage: 24 VDC ±10% Power consumption: DC1.7 W max (not including sensor’s current consumption) Operation time: 100 ms max. (not including the sensor’s response time) response time max. (not including the sensor’s response time) ...

Page 10

... Tel. 1/888/510-4357 Tel. 1/866/986-6766 30 20 5.5 2-Mounting holes (13.75) 16.5 3. 2-Mounting holes Beam E 4-Mounting holes 6.5 dia. 13.75 2-Mounting holes 9 dia Number — B/5 For the Latest Information On the Internet: www.sti.com or www.omron.ca F3SJ-A Mounting Screw Holes 4- 2- D15 D ...

Page 11

... F3SJ-A1487P14 F3SJ-A0425P14 46 425 F3SJ-A1559P14 F3SJ-A0443P14 48 443 F3SJ-A1631P14 F3SJ-A0461P14 50 461 f3SJ-A20, f3SJ-A20-tS* Series F3SJ-A0479P14 52 479 F3SJ-A0245P20 F3SJ-A0497P14 54 497 F3SJ-A0275P20 F3SJ-A0515P14 56 515 F3SJ-A0305P20 F3SJ-A0533P14 58 533 F3SJ-A0335P20 F3SJ-A0551P14 60 551 F3SJ-A0365P20 F3SJ-A0569P14 62 569 F3SJ-A0395P20 F3SJ-A0587P14 64 587 F3SJ-A0425P20 F3SJ-A0605P14 66 605 F3SJ-A0455P20 F3SJ-A0623P14 68 623 F3SJ-A0485P20 F3SJ-A0659P14 ...

Page 12

... F3SJ-A1870P30 F3SJ-A0945P30 38 945 F3SJ-A1995P30 F3SJ-A0970P30 39 970 F3SJ-A2120P30 F3SJ-A0995P30 40 995 F3SJ-A2245P30 F3SJ-A1020P30 41 1020 F3SJ-A2370P30 F3SJ-A1045P30 42 1045 F3SJ-A2495P30 F3SJ-A1070P30 43 1070 f3SJ-A55 Series F3SJ-A1095P30 44 1095 F3SJ-A0270P55 F3SJ-A1120P30 45 1120 F3SJ-A0320P55 F3SJ-A1145P30 46 1145 F3SJ-A0370P55 F3SJ-A1170P30 47 1170 F3SJ-A0420P55 F3SJ-A1195P30 48 1195 F3SJ-A0470P55 F3SJ-A1220P30 49 1220 F3SJ-A0520P55 Accessories model ...

Page 13

... DC semiconductor safety output F3SX-N-L2R Can connect 2 sets of F3SJ-As and emergency stop switch Relay output (2 N N/C) F3SX-N-L2L2R Can connect 4 sets of F3SJ-As and emergency stop switch Relay output (2 N N/C) connection cable for f3SX (F3SX to F39-CN5) F39-JC1T F3SX connection cable (3.3 ft.) F39-JC3T F3SX connection cable ...

Page 14

... Series connection cable for receiver, purchase additionally for series connection when using the water-resistant case The setting tools described above can be connected only to F3SJ-A models with built-in software of Ver later. 5 Note that the setting tools cannot be used with products shipped prior to December 2005. The setting tools cannot be used for setting parameters on the F3SJ-A£ ...

Related keywords