E3X-MDA8 Omron Automation, E3X-MDA8 Datasheet - Page 2

no-image

E3X-MDA8

Manufacturer Part Number
E3X-MDA8
Description
Amplifier; Photoelectric; Dual Fiber Sensing Mode; PNP; 12 to 24 VDC; 45 mA
Manufacturer
Omron Automation
Type
Fiber Opticr
Datasheet

Specifications of E3X-MDA8

Body Style
Rectangular
Current, Consumption
45 mA
Current, Switching
50 mA
Function
Fiber Optic
Indicator
LED
Ip Rating
IP50
Material, Casing
Polybutylene Terephthalate (PBT)
Material, Cover
Polycarbonate (PC)
Mounting Type
DIN Rail
Output
PNP
Primary Type
Photoelectric
Sensing Mode
Through-Beam
Standards
CE Marked, IEC Approved
Technology
Photoelectric
Temperature, Operating
-25 to +55 °C
Termination
Connector
Time, Response
130 μs
Voltage, Supply
24 VDC
Voltage, Switching
26.4 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Industry Leading Two Amplifiers Loaded in a Small Body
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
(compared to the value per channel of the former
model)
Simpler Digital Fiber Sensors
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
High-speed and High-resolution Analog Output Supports Wide Variety of Applications
Analog Control Output
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
Area Output Function Area Judgment Is Possible
Only one sensor is enough for area judgment for height or others that has re-
quired multiple sensors.
Setting two threshold values allows easy output inside and outside range.
Remote Input Function Sensors Controlled from Outside
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Equipped with an Industry's First ATC Function that Resolves Problems
at Manufacturing Sites
OMRON’s unique algorism is equipped to
distinguish dust or dirt and the change of
workpieces. Automatic correction of threshold
values by sensors in accordance with changes
prevents malfunctions and improves the operating
rates of machines. The ATC function is especially
effective for the applications that require high-
resolution detection.
Models available for a wide variety of applications at manufacturing sites
. . . . Advanced ATC Models
ON/OFF
Analog
Fixed Threshold Value Method (Conventional Models)
Incident level
(digital value)
. . . . Advanced, Twin-
. . . . Simple & Easy Single-function Models
Output
2000
output Models
ON
OFF
20mm
Malfunction
High-speed and High Resolution
Detection modes can be switched in accordance with applications.
High-speed response of 80 s (super-high-speed mode) supports the
positioning controls that require high-speed control.
. . . . Advanced, External-
Adjustment is required
Area Output
Sheet Displacement
Incident
level
10mm
1000
Output
OFF
2000
ON
input Models
1800
Threshold value
set as an
absolute value
Time
. . . . 2-channel models
2-channel models
E3X-MDA
Incident level
Corrected Threshold Value Method (ATC Models)
(digital value)
Output
2000
ON
OFF
Time
Threshold
value 2
Threshold
value 1
Threshold value is corrected every 30 seconds *
Current value
*
Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition range.
Malfunctions are prevented
Operation mode
selection switch
E3X-DA-S/MDA
Key lock switch
. . . . Advanced Analog
Threshold value teaching
TEACH key
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
Tablet length detection
Threshold value
Liquid crystal board installation and alignment check
Output Models
Sticker detection
−10%
UP/DOWN keys
Threshold value adjustment
Threshold value
set as a relative
value
Time
2