E3X-MDA8 Omron Automation, E3X-MDA8 Datasheet - Page 6

no-image

E3X-MDA8

Manufacturer Part Number
E3X-MDA8
Description
Amplifier; Photoelectric; Dual Fiber Sensing Mode; PNP; 12 to 24 VDC; 45 mA
Manufacturer
Omron Automation
Type
Fiber Opticr
Datasheet

Specifications of E3X-MDA8

Body Style
Rectangular
Current, Consumption
45 mA
Current, Switching
50 mA
Function
Fiber Optic
Indicator
LED
Ip Rating
IP50
Material, Casing
Polybutylene Terephthalate (PBT)
Material, Cover
Polycarbonate (PC)
Mounting Type
DIN Rail
Output
PNP
Primary Type
Photoelectric
Sensing Mode
Through-Beam
Standards
CE Marked, IEC Approved
Technology
Photoelectric
Temperature, Operating
-25 to +55 °C
Termination
Connector
Time, Response
130 μs
Voltage, Supply
24 VDC
Voltage, Switching
26.4 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
*2. PNP output is as follows: Operate: 53 s, reset: 55 s.
*3. When counter is enabled: 80 s for operate and reset respectively.
*4. When differential output is selected for the output setting, the second channel output is 200 s for operation and reset respectively.
*5. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*6. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
Item
Light source (wavelength)
Power supply voltage
Power consumption
Control
output
Protection circuits
Response
time
Sensitivity setting
Functions
Display
and the Mobile Console will not function.
ON/OFF output
Analog output
Super-high-speed mode
High-speed mode Operate or reset: 250 s
Standard mode
High-resolution mode
Power tuning
Differential de-
tection
Timer function
Automatic power
control (APC)
Zero-reset
Initial reset
Mutual interfer-
ence prevention
Counter
I/O setting
Model
Type
Red LED (635 nm)
12 to 24 VDC 10%, ripple (p-p) 10% max.
1,080mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Reverse polarity for power supply connection, output short-circuit
Operate: 48 s,
reset: 50 s *1, *2, *3
Operate or reset: 1ms
Operate or reset: 4ms
Teaching or manual method
Light emission power and reception gain, digital control method
Switchable between single edge and double edge detection mode
Single edge: Can be set to 250 s, 500 s, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 s, 1 ms, 2 ms, 20 ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-
ms increments, and 1 to 5 s set in 1 s-increments)
High-speed control method for emission current
Negative values can be displayed. (Threshold value is shifted.)
Settings can be returned to defaults as required.
Possible for up to 10 Units *5
Switchable between
up counter and down
counter.
Set count:
0 to 9,999,999
External input set-
ting (Select from
teaching, power tun-
ing, zero reset, light
OFF, or counter re-
set.)
Operation indicator
(orange), Power
Tuning indicator (or-
ange)
External input models
E3X-DA@RM-S
Operate or reset:
80 s *1
Output setting
(Select from channel
2 output, area out-
put, or self-diagno-
sis.)
Operation indicator for channel 1 (orange),
Operation indicator for channel 2 (orange)
Twin output models
E3X-DA@TW-S
---
Advanced models
Operate or reset:
130 s *1
Output setting (Se-
lect from channel 2
output, area output,
self-diagnosis out-
put, or ATC error
output)
ATC function models Analog output models
E3X-DA@AT-S
---
Response speed/
repeat accuracy
Control output
Voltage output: 1 to
5 VDC
(Connection load 10
k min.)
Temperature char-
acteristics
0.3%F.S./ C
Super-high-speed mode:
80 s/1.5%F.S.
High-speed mode:
250 s/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
Operate or reset:
80 s *1
Analog output set-
ting (offset voltage
adjustable)
Operation indicator
(orange),
Power Tuning indi-
cator (orange)
E3X-DA@AN-S
E3X-DA-S/MDA
---
Operate or reset:
130 s *1, *4
Operate or reset: 450 s
Possible for up to 9
Units (18 channels) *6
Output setting
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Operation indicator for
channel 1 (orange),
Operation indicator for
channel 2 (orange)
2-channel models
E3X-MDA@
---
6