ST62T09CM6 STMicroelectronics, ST62T09CM6 Datasheet - Page 78

Microcontrollers (MCU) OTP EPROM 1K No Intf

ST62T09CM6

Manufacturer Part Number
ST62T09CM6
Description
Microcontrollers (MCU) OTP EPROM 1K No Intf
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST62T09CM6

Processor Series
ST62T0x
Core
ST6
Data Bus Width
8 bit
Program Memory Type
EPROM
Program Memory Size
1 KB
Data Ram Size
64 B
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
12
Number Of Timers
2
Operating Supply Voltage
3 V to 6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOP-20
Minimum Operating Temperature
- 40 C
On-chip Adc
8 bit
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST62T09CM6
Manufacturer:
ST
0
Part Number:
ST62T09CM6
Quantity:
4 600
ST6208C/ST6209C/ST6210C/ST6220C
EMC CHARACTERISTICS (Cont’d)
10.7.2 Absolute Electrical Sensitivity
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the AN1181 application note.
10.7.2.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (3 positive then 3 nega-
tive pulses separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends of the
number of supply pins of the device (3 parts*(n+1)
supply pin). Two models are usually simulated:
Human Body Model and Machine Model. This test
conforms to the JESD22-A114A/A115A standard.
See
Human Body Model Test Sequence
– C
Absolute Maximum Ratings
Notes:
1. Data based on characterization results, not tested in production.
Figure 57. Typical Equivalent ESD Circuits
78/104
1
ator.
HIGH VOLTAGE
V
V
GENERATOR
Symbol
ESD(HBM)
ESD(MM)
L
Figure 57
is loaded through S1 by the HV pulse gener-
PULSE
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
and the following test sequences.
S1
C
L
100pF
HUMAN BODY MODEL
Ratings
R=1500
ST6
T
T
A
A
S2
+25°C
+25°C
– S1 switches position from generator to R.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
Machine Model Test Sequence
– C
– S1 switches position from generator to ST6.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
– R (machine resistance), in series with S2, en-
to the ST6 occurs.
delivery period to ensure the ST6 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
ator.
delivery period to ensure the ST6 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
sures a slow discharge of the ST6.
HIGH VOLTAGE
GENERATOR
L
is loaded through S1 by the HV pulse gener-
Conditions
PULSE
L
S1
L
through R (body resistance)
to the ST6 occurs.
C
L
200pF
Maximum value
MACHINE MODEL
ST6
2000
200
1)
Unit
V
S2

Related parts for ST62T09CM6