MCP2120-I/P Microchip Technology, MCP2120-I/P Datasheet - Page 17

IC ENCODER/DECODR INFRARED 14DIP

MCP2120-I/P

Manufacturer Part Number
MCP2120-I/P
Description
IC ENCODER/DECODR INFRARED 14DIP
Manufacturer
Microchip Technology
Type
Infrared Encoder/Decoderr
Datasheets

Specifications of MCP2120-I/P

Package / Case
14-DIP (0.300", 7.62mm)
Voltage - Supply, Analog
2.5 V ~ 5.5 V
Voltage - Supply, Digital
2.5 V ~ 5.5 V
Mounting Type
Through Hole
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Ic Function
Infrared Encoder/Decoder
Supply Voltage Range
2.5V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
DIP
No. Of Pins
14
Leaded Process Compatible
No
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP212XDM - BOARD DEVELOPMENT IRDA
Applications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP2120-I/P
Manufacturer:
ROHM
Quantity:
1 400
Part Number:
MCP2120-I/P
Quantity:
22
Part Number:
MCP2120-I/P
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
4.3
FIGURE 4-3:
TABLE 4-3:
© 2007 Microchip Technology Inc.
AC Characteristics
Note 1:
Param.
No.
1A
1C
1
3
4
OSC1
2:
3:
Timing Diagrams and Specifications
Data in the Typical (“Typ”) column is at 5V, +25°C unless otherwise stated. These parameters are for
design guidance only and are not tested.
All specified values are based on characterization data for that particular oscillator type under standard
operating conditions with the device executing code. Exceeding these specified limits may result in an
unstable oscillator operation and/or higher than expected current consumption.
When an external clock input is used, the “max” cycle time limit is “DC” (no clock) for all devices.
A duty cycle of no more than 60/40 (High Time / Low Time or Low Time / High Time) is recommended for
external clock inputs.
TosR,
F
TosL,
T
E
TosH
TosF
Sym
OSC
OSC
CLK
EXTERNAL CLOCK TIMING REQUIREMENTS
External CLKIN Period
Oscillator Period
External CLKIN
Frequency
Oscillator Frequency
Clock Error
Clock in (OSC1)
Low or High Time
Clock in (OSC1)
Rise or Fall Time
External Clock Timing
Q4
Characteristic
(2,3)
(2)
Q1
1
(2)
(2,3)
Standard Operating Conditions (unless otherwise specified)
Operating Temperature
Operating Voltage V
Characteristics”
Q2
Min
DC
50
50
10
2
Typ
3
(1)
Q3
DD
3
range is described in Section 4.1 “DC
Max
0.01
500
20
20
15
–40°C ≤ T
Q4
4
Units
MHz
MHz
ns
ns
ns
ns
%
A
4
≤ +85°C (industrial)
MCP2120
Q1
Conditions
DS21618B-page 17