Greatly Improved Ladder Monitor.
Thoroughly focused on Visibility and Ease of Use.
I/O comments can be read directly from the PLC in a single operation,
so no extra work to show I/O comments.
The Ladder Diagram can be fully displayed on the entire screen,
so it is easier to see and work.
The ability to change the color and size in which the Ladder Monitor is displayed greatly improves visibility.
The ladder diagram can be displayed on the entire screen (800 x 600 dots) even for the NS12 with a
maximum display of 17 rows and 16 columns of a ladder diagram.
The ladder diagram is easy to see display in black and green.
Automatically jumping from the alarm message
Easy checking the alarm bit and shortens searching time.
When an alarm occurs, touch the message to automatically search for the alarm bit (output bit) for the alarm.
This enables you to quickly check the alarm address and investigate why the bit turned ON.
Read I/O comments directly from the PLC. I/O comments do not have to be stored in a Memory Card.
ALARM
Select Read I/O Comment
Reading from the Menu.
The I/O comments are
displayed.
The cursor is displayed with a red frame.
This is useful to specify the program section, execute a
search, and to display the search results.
Up to three lines can be used for comments.
The comment display can be selected from three lines,
one line, or no comments.
Note: Not supported for the 5.7-inch model.
Found it!
“Find Back” , “Find Next” , CX-Programmer useful Function Also Supported by the NS-series.
Reduced Time to Investigate Which Output or Input Is Causing the Problem
For example, easily search for the cause using steps 1 to 6 as shown in the following figure.
Force-setting and force-resetting are possible,
so conditions can be established as required.
Locations that have been force-set are displayed in pink and can be checked at a glance.
Minor changes in values of timers or counters can be made without Support Software.
Check and Change I/O While You View the Ladder Diagram on the I/O Monitor
Display and change the present value by specifying the address. It is also possible to force-set/reset bits with the I/O monitor.
Find the address at specified by the cursor.
Find the output from the input bit or find the input bit from the output
at the cursor.
Return to the previous search position.
Yes, the problem
Select the input bit for which the output will be forced ON.
Make the selection with
the I/O monitor by touching
the screen.
So is it input CIO
21.01 after all?
Is this input the cause?
What output corresponds
to this input?
Which of these two
inputs is the cause? Let’s
look at CIO 21.00 first.
is here!
Supported Devices
Function
Changing the present value
of the address selected with
the Change Value Button
Forced ON
CJ2
Select the address
by touching the panel.
CS1/CJ1
Note: Operation is not supported for a connection
Operation with NS-series PT.
with a CP1E PLC.
Double-click
Select the Forced Set Option and then
press the Update Button.
CP1 (See note.)
There’ s no problem with
input CIO 21.00. Let’ s go back to
the previous program section.
Why is this output
not turning ON?
Why is this
output not turning ON?
CX-Programmer
Space Key
Multi-vendor Support
N Key