R88A-CAWE020B Omron, R88A-CAWE020B Datasheet - Page 449

no-image

R88A-CAWE020B

Manufacturer Part Number
R88A-CAWE020B
Description
POWER CABLE W/BRAKE 20M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAWE020B

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ACAWE020B
Appendix
H Connection Example 10: Connecting to a SYSMAC CS1W-HCP22-V1
Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver.
Note 2. Leave unused signal lines open and do not wire them.
Note 3. Use the 24-V DC power supply for command pulse signals as a dedicated power supply.
Note 4. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric) or equivalent.
Note 5. Do not share the 24-V DC power supply for the break with the 24-V DC power supply for con-
* The I/O signals of the CS1W-HCP22-V1 depend on the internal memory area allocations. Change the
wiring according to the allocations.
Customizable Counter Unit
CS1W-HCP22-V1
24-VDC power supply (for output)
Common
Pulse
out-
put 1
Phase-Z LD+
Phase-Z LD–
24 V (for output)
Deviation counter clear*
Common (for output)
Deviation positioning completed signal*
Servo ON*
Alarm reset *
Origin proximity input signal*
CCW limit input signal*
CW limit input signal*
Common (for input)
I/O connector
trol.
CCW (1.6 kΩ)
CW (1.6 kΩ)
Special I/O connector
Name
3-phase 200/230 V AC 50/60 Hz
Class-3 ground
R88D-WTj
Shell
Main circuit power supply
White
Red
Blue
Green/
Yellow
Encoder Cable
R88A-CRWj
R88A-CRWjR
Power Cable
R88A-CAWj
R88A-CAWjR
DC reactor
Main circuit contact
Surge killer
Chapter 6
R88M-Wj
6-11