SI3015-F-FS Silicon Laboratories Inc, SI3015-F-FS Datasheet - Page 34

IC ISOMODEM LINE-SIDE 16SOIC

SI3015-F-FS

Manufacturer Part Number
SI3015-F-FS
Description
IC ISOMODEM LINE-SIDE 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheets

Specifications of SI3015-F-FS

Package / Case
16-SOIC (3.9mm Width)
Data Format
V.90
Interface
Serial
Voltage - Supply
3.3 V ~ 5 V
Mounting Type
Surface Mount
Product
Modem Chip
Supply Voltage (min)
3 V
Supply Current
26 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Baud Rates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3015-F-FS
Quantity:
3 000
Part Number:
SI3015-F-FSR
Manufacturer:
SAMSUNG
Quantity:
2 000
Part Number:
SI3015-F-FSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si2403
34
S-Register
(Decimal)
30
38
40
42
43
44
50
51
Disconnect Activity Timer—Sets the length of time that
the modem stays online before disconnecting with no
activity on the serial port, parallel port, or telephone
line (Ring, hookswitch flash, or caller ID). This feature
is disabled if set to 0.
Hang Up Delay Time—Maximum delay between
receipt of ATH0 command and hang up. If time out
occurs before all data can be sent, the NO CARRIER
(3) result code is sent (operates in V.42 mode only).
“OK” response is sent if all data is transmitted before
timeout. S38 = 255 disables timeout and modem dis-
connects only if data is successfully sent or carrier is
lost.
Data Pattern - Data pattern generated during &T4 and
&T5 transmit tests.
0 – All spaces (0s)
1 – All marks (1s)
2 – Random data
Blacklisting - The Si2403 will not dial the same number
more than three times in three minutes. An attempt to
dial a fourth time within three minutes will result in a
“BLACKLISTED” result code. If the blacklist memory is
full, any dial to a new number will result in a “BLACK-
LIST FULL” result code. Numbers are added to the
blacklist only if the modem connection fails. The %B
command will list the numbers on the blacklists.
0: disabled
1: enabled
Dial Attempts to Blacklist.
When blacklisting is enabled with S42, this value con-
trols the number of dial attempts that will result in a
number being blacklisted.
Blacklist Timer.
Period during which blacklisting is active
Minimum On-Hook Time—Modem will remain on-hook
for S50 seconds. Any attempt to go off-hook will be
delayed until this timer expires.
Number to start checking for an outside line on a PBX.
Table 13. S-Register Descriptions (Continued)
Function
Definition
Rev. 1.2
0 (disabled)
(Decimal)
Default
180
20
0
0
4
3
1
Range
0–255
0–255
0–255
0–255
0–2
0–1
0–4
0–9
seconds
seconds
seconds
minutes
Units

Related parts for SI3015-F-FS