AD7150BRMZ Analog Devices Inc, AD7150BRMZ Datasheet - Page 17

IC CAP CONV 2CH ULT LP 10MSOP

AD7150BRMZ

Manufacturer Part Number
AD7150BRMZ
Description
IC CAP CONV 2CH ULT LP 10MSOP
Manufacturer
Analog Devices Inc
Type
Capacitance-to-Digital Converterr
Datasheet

Specifications of AD7150BRMZ

Design Resources
Using AD7150 for Proximity Sensing Appls (CN0095)
Input Type
Voltage
Output Type
Digital
Interface
2-Wire Serial
Current - Supply
120µA
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Resolution (bits)
12bit
Data Interface
2-Wire, I2C, Serial
Supply Voltage Range - Analog
2.7V To 3.6V
Supply Current
100µA
Digital Ic Case Style
SOP
No. Of Pins
10
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7150EBZ - BOARD EVAL FOR AD7150
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7150BRMZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7150BRMZ
Manufacturer:
ADI
Quantity:
103
Company:
Part Number:
AD7150BRMZ
Quantity:
6 000
Part Number:
AD7150BRMZ-REEL
Manufacturer:
ON
Quantity:
4 300
Part Number:
AD7150BRMZ-REEL
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7150BRMZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
TIMEOUT REGISTERS
Ch1 Address Pointer 0x0A
Ch2 Address Pointer 0x0D
8 Bits, Read/Write, Factory Preset 0x86
Table 9. Timeout Register Bit Map
Bit
Mnemonic
Default
These registers set timeouts for the adaptive threshold mode.
The approaching timeout starts when the CDC data crosses the
data average ± sensitivity band toward the threshold, according
to the selected positive, negative, or window threshold mode.
The approaching timeout elapses after the number of conversion
cycles equals 2
most significant bits of the timeout register.
The receding timeout starts when the CDC data crosses the
data average ± sensitivity band away from the threshold,
according to the selected positive or negative threshold mode.
The receding timeout is not used in the window threshold
mode. The receding timeout elapses after the number of
conversion cycles equals 2
value of the four least significant bits of the timeout register.
TimeOutApr
, where TimeOutApr is the value of the four
TimeOutRec
TimeOutApr
Bits [7:4]
, where TimeOutRec is the
0x08
TimeOutRec
Bits [3:0]
0x06
Rev. 0 | Page 17 of 28
When either the approaching or receding timeout elapses (that
is, after the defined number of CDC conversions is counted),
the data average (and thus the thresholds) is forced to follow the
new CDC data value immediately.
When the timeout register equals 0, timeouts are disabled.
DATA AVERAGE
DATA AVERAGE
DATA AVERAGE
DATA AVERAGE
+ SENSITIVITY
+ SENSITIVITY
THRESHOLD
THRESHOLD
After a Large Change in CDC Data Away from Threshold
After a Large Change in CDC Data Toward Threshold
Figure 39. Threshold Timeout Approaching
Figure 40. Threshold Timeout Receding
AWAY FROM THE THRESHOLD
LARGE CHANGE IN DATA
TIMEOUT APPROACHING
TIMEOUT RECEDING
LARGE CHANGE IN DATA
TOWARDS THRESHOLD
TIME
TIME
AD7150