PCA9541D/03,112 NXP Semiconductors, PCA9541D/03,112 Datasheet - Page 12

IC I2C 2:1 SELECTOR 16SOIC

PCA9541D/03,112

Manufacturer Part Number
PCA9541D/03,112
Description
IC I2C 2:1 SELECTOR 16SOIC
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA9541D/03,112

Package / Case
16-SOIC (3.9mm Width)
Applications
2-Channel I²C Multiplexer
Interface
I²C, SMBus
Voltage - Supply
2.3 V ~ 5.5 V
Mounting Type
Surface Mount
Logic Family
PCA9541
Operating Supply Voltage
2.3 V to 5.5 V
Power Dissipation
400 mW
Operating Temperature Range
- 40 C to + 85 C
Input Voltage
7 V
Logic Type
I2C Bus
Maximum Clock Frequency
400 KHz
Mounting Style
SMD/SMT
Output Current
25 mA
Output Voltage
2.3 V to 5.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
935273317112
PCA9541D/03
PCA9541D/03
NXP Semiconductors
PCA9541_7
Product data sheet
Table 9.
As a master reads its Control Register
[1]
Table 10.
[1]
Switch to the new channel is done when the master initiating the switch request sends a
STOP command to the PCA9541.
If either master wants to change the connection of the downstream channel, it needs to
write to its Control Register (Reg#01), and then send a STOP command because an
update of the connection to the downstream according to the values in the two internal
Control Registers happens only on a STOP command. Writing to one control register
followed by a STOP condition on the other master's channel will not cause an update to
the downstream connection.
When both masters request a switch to their own channel at the same time, the master
who last wrote to its Control Register before the PCA9541 receives a STOP command
wins the switching sequence. There is no arbitration performed.
The Auto Increment feature (AI = 1) allows to program the PCA9541 in 4 bytes:
Start
111A3A2A1A0 + 0
00010000
Data Reg#00
Data Reg#01
Stop
NMYBUS
0
1
0
1
NBUSON
0
1
0
1
MYBUS and NMYBUS is an exclusive-OR type function where:
Equal values (00b or 11b) means that the master reading its Control Register has control of the bus.
Different values (01b or 10b) means that the master reading its Control Register does not have control of
the bus.
BUSON and NBUSON is an exclusive-OR type function where:
Equal values (00b or 11b) means that the connection between the upstream and the downstream channels
is off.
Different values (01b or 10b) means that the connection between the upstream and the downstream
channels is on.
[1]
[1]
MYBUS and NMYBUS truth table
BUSON and NBUSON truth table
MYBUS
0
0
1
1
BUSON
0
0
1
1
[1]
[1]
PCA9541 Address + Write
Select Reg#00 with AI = 1
Interrupt Enable Register data
Control Register data
Rev. 07 — 2 July 2009
Slave channel
The master reading this combination has control of the bus.
The master reading this combination does not have control of the bus.
The master reading this combination does not have control of the bus.
The master reading this combination has control of the bus.
Slave channel
off
on
on
off
2-to-1 I
2
C-bus master selector with interrupt logic and reset
PCA9541
© NXP B.V. 2009. All rights reserved.
12 of 41

Related parts for PCA9541D/03,112