W83627EHG Nuvoton Technology Corporation of America, W83627EHG Datasheet - Page 45

no-image

W83627EHG

Manufacturer Part Number
W83627EHG
Description
IC I/O CONTROLLER 128-QFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheets

Specifications of W83627EHG

Applications
PC's, PDA's
Interface
LPC
Voltage - Supply
3.3V
Package / Case
128-XFQFN
Mounting Type
Surface Mount
Pin Count
128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83627EHG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W83627EHG
Quantity:
23
Company:
Part Number:
W83627EHG
Quantity:
672
Part Number:
W83627EHG-A
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W83627EHG-C
Manufacturer:
Winbond
Quantity:
1 000
Part Number:
W83627EHG-UB5885009AH-H VERSION
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
6.6.3
6.6.3.1. Temperature sensor 1(SYSTIN) SMI# interrupt has 3 modes
(1) Comparator Interrupt Mode
(2) Two-Times Interrupt Mode
(3) One-Time Interrupt Mode
127'C
T
SMI#
HYST
T
Setting the T
following are two kinds of interrupt modes, which are selected by Bank0 Index 4Ch bit5 :
OI
Setting the T
the Comparator Interrupt Mode. Temperature exceeds T
interrupt and this interrupt will be reset by reading all the Interrupt Status Register. Once an
interrupt event has occurred by exceeding T
T
has occurred by exceeding T
will continue to occur in this manner until the temperature goes below T
Temperature exceeding T
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status
Register. Once an interrupt event has occurred by exceeding T
remains above the T
Temperature exceeding T
cause an interrupt. Once an interrupt event has occurred by exceeding T
T
O
HYST,
Temperature SMI# mode
, the interrupt will occur again when the next conversion has completed. If an interrupt event
an interrupt will not occur again until the temperature exceeding T
HYST
HYST
Figure 6.14
*
lower than T
(Temperature Hysteresis) limit to 127°C will set temperature sensor 1 SMI# to
*Interrupt Reset when Interrupt Status Registers are read
*
HYST
, the interrupt will not occur. (Figure 6.15 )
*
O
O
causes an interrupt and then temperature going below T
causes an interrupt and then temperature going below T
O
O
will set temperature sensor 1 SMI# to the Interrupt Mode. The
and not reset, the interrupts will not occur again. The interrupts
W83627EHF/EF, W83627EHG/EG
*
O
- 39 -
, then reset, if the temperature remains above the
T
HYST
SMI#
T
OI
O
(Over Temperature) Limit causes an
O
Publication Release Date: Nov. 2006
, then reset, if the temperature
*
Figure 6.15
O
O
. (Figure 6.14 )
O
. (Figure 6.16 )
, then going below
*
HYST
HYST
Revision 1.3
will also
will not
*

Related parts for W83627EHG