2-532431-2 TE Connectivity, 2-532431-2 Datasheet
2-532431-2
Specifications of 2-532431-2
Related parts for 2-532431-2
2-532431-2 Summary of contents
Page 1
... Housing: Therm oplastic, glass filled, UL 94V-0 3.3. Ratings ! Current peres m axim um per contact, 2.25 am peres continuous per contact at room am bient, with not m ore than 2 adjacent or opposing circuits carrying this current. ! Operating Tem perature: -65 to 125°C for gold contacts ©2011 Tyco Electronics Corporation, | Indicates change a TE Connectivity Ltd ...
Page 2
... Test Voltage Altitude (rm s) Feet 900 Sea Level 200 70,000 2 m illiam peres m axim um leakage current. 5000 m egohm s m inim um initial. MECHANICAL No discontinuities greater than 1 m icrosecond. No physical dam age. No discontinuities greater than 1 m icrosecond. No physical dam age. ...
Page 3
... Mate and unm ate pin and receptacle connectors for 250 cycles. TE Spec 109-27. Subject term inal posts m ounted on printed circuit boards to solder bath at 260 ±5 C for 10 ±2 seconds. Spec 109-63-3. Fully insert pin into printed wiring board hole. Apply an axial load of 10 pounds for 10 seconds. ...
Page 4
... Numbers indicate sequence in which tests are performed. (c) This test is not applicable to ACTION PIN connectors. (d) Sizing contacts three times is required only before the initial test. Rev C Test Group ( Test Sequence (b) 1,20 1,19 1,13 6,16 6,15 5,9,15 5,9,14 7,10 8, 4,11,17 4,10,16 5 7,12,18 7,11, 3,10,19 3,12, Figure 2 108-9063 4 1 ...
Page 5
... Sheets and shall be selected at random from current production. Test groups 1, 2 and 3 shall each consist of 3 connectors of the greatest num ber of position of each type offered. Two additional specim ens shall be selected from least num ber of positions offered and tested with group 2. Test group 4 shall consist of 20 contacts. ...
Page 6
... Term ination Resistance Measurem ent Points Note: (1) Tolerance: ±.005 as applicable, unless otherwise specified. (2) Material: Tool steel (3) Heat Treat: Rockwell C 50-55 (4) Gage Surface: Shall be clean of contam inants or lubricants Rev C Figure 3 Gage Num ber A +.0001 1 .0250 -.0000 +0000 2 .0260 -.0001 Figure 4 Gage Insertion and Extraction 108-9063 ...