RN-XV

Manufacturer Part Number
RN-XV
Description
MODULE 802.11B/G 2.4GHZ
Manufacturer
Roving Networks Inc
Series
-r
Datasheets

Specifications of RN-XV

Frequency
2.4GHz
Data Rate - Maximum
54Mbps
Modulation Or Protocol
802.11b/g
Applications
General Purpose
Power - Output
12dBm
Sensitivity
-83dBm
Voltage - Supply
3 V ~ 3.7 V
Current - Receiving
40mA
Current - Transmitting
180mA
Data Interface
PCB, Through Hole
Memory Size
-
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
740-1044
RN-XV-W
RN-XVEE
XVEE
3.
There are two modes in the WiFly module, namely data mode and command mode. In data mode, the
module is ready to either accept incoming connections or initiate outgoing connections. To configure the
parameters and/or to view the current configuration, the module must be put into command mode (also
called configuration mode). At any given time, the module will either be in command mode or in data
mode.
Upon power up, the device will be in data mode. To enter command mode, exactly the escape sequence (set
to three characters, $$$ by default) must be sent. The device will respond with CMD indicating it is in
command mode.
NOTE: There is no carriage return (<cr>) after the $$$ to enter command mode.
For example: To enter command mode from data mode, you need to send
$$$
$$$<cr>
NOTE: There is a 250ms buffer before and after the escape sequence. If any characters are sent before or
after the escape sequence within this interval of 250ms, the WiFly module will treat it as data and pass it
over the TCP or UDP socket. It will not enter command mode.
While in command mode, the device will accept ASCII bytes as commands. Each command ends with a
carriage return <cr>. To exit command mode, send exit<cr>. The device will respond with EXIT
indicating that it has exited command mode and switched into data mode.
Parameters, such as the SSID, channel, IP address, Serial Port settings, and all other settings can be viewed
and configured in command mode.
ASCII characters can be sent through a terminal emulator connected to the UART or via Telnet. When
using the UART interface, communications settings should match the stored settings used by the WiFly
module. The default is 9600 baudrate, 8 bits, No Parity, 1 stop bit, and hardware flow control disabled.
Please DO NOT use HyperTerminal. Use TeraTerm as your terminal emulator. TeraTerm can be
downloaded from our website:
Configuration
3.1. Entering Command Mode
www.rovingnetworks.com
809 University Avenue
//The module will respond with CMD indicating it is in command mode.
//The module may not enter command mode
Los Gatos, CA 95032
http://www.rovingnetworks.com/support
~ 6 ~
Tel (408) 395-6539
• info@RovingNetworks.com
WiFly-RN-UM
WiFly GSX/EZX
5/4/2011

Related parts for RN-XV