LH28F008SCT-V12 Sharp Electronics, LH28F008SCT-V12 Datasheet - Page 17

no-image

LH28F008SCT-V12

Manufacturer Part Number
LH28F008SCT-V12
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F008SCT-V12

Cell Type
NOR
Density
8Mb
Access Time (max)
120ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
20b
Operating Supply Voltage (typ)
5V
Operating Temp Range
0C to 70C
Package Type
TSOP-I
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Word Size
8b
Number Of Words
1M
Supply Current
50mA
Mounting
Surface Mount
Pin Count
40
Lead Free Status / Rohs Status
Not Compliant
FULL STATUS CHECK PROCEDURE
Read Status Register
Data (See Above)
Check if Desired
Status Register
Block Address
Block Address
Block Erase
Block Erase
Write D0H,
Write 20H,
Full Status
Successful
Complete
SR.4, 5 =
SR.7 =
SR.3 =
SR.1 =
SR.5 =
Read
Start
0
0
0
0
1
0
1
1
1
1
Block Erase
Command Sequence
No
Device Protect Error
Suspend
V
PP
Fig. 3 Automated Block Erase Flowchart
Block Erase
Range Error
Error
Error
Suspend Block
Erase Loop
Yes
- 17 -
OPERATION
OPERATION COMMAND
Write
Write
Read
Standby
Standby
Standby
Standby
Standby
Repeat for subsequent block erasures.
Full status check can be done after each block erase or after
a sequence of block erasures.
Write FFH after the last block erase operation to place device
in read array mode.
SR.5, SR.4, SR.3 and SR.1 are only cleared by the Clear
Status Register command in cases where multiple blocks
are erased before full status is checked.
If error is detected, clear the status register before attempting
retry or other error recovery.
BUS
BUS
Erase Setup
COMMAND
Confirm
Erase
Check SR.3
1 = V
Check SR.4, 5
Both 1 = Command Sequence Error
Data = 20H
Addr = Within Block to be Erased
Data = D0H
Addr = Within Block to be Erased
Status Register Data
Check SR.7
1 = WSM Ready
0 = WSM Busy
Check SR.1
1 = Device Protect Detect
RP# = V
Only required for systems
implementing lock-bit configuration
Check SR.5
1 = Block Erase Error
PP
Error Detect
IH
, Block Lock-Bit is Set
COMMENTS
COMMENTS