LH28F160S3HT-L10 Sharp Electronics, LH28F160S3HT-L10 Datasheet - Page 26

no-image

LH28F160S3HT-L10

Manufacturer Part Number
LH28F160S3HT-L10
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F160S3HT-L10

Cell Type
NOR
Density
16Mb
Interface Type
Parallel
Boot Type
Not Required
Address Bus
21/20Bit
Operating Supply Voltage (typ)
3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7/3.3/5V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
2M/1M
Supply Current
30mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LH28F160S3HT-L10A
Manufacturer:
MEDIATEK
Quantity:
3 293
sharp
FULL STATUS CHECK PROCEDURE
Read Status Register
Write 40H or 10H,
Data and Address
Data(See Above)
Check if Desired
Word/byte Write
Word/Byte Write
Write Word/Byte
Status Register
Read Status
Successful
Write 70H
Full Status
Complete
Register
Address
SR.7=
SR.7=
SR.3=
SR.1=
SR.4=
Start
Read
1
1
0
0
0
0
0
1
1
1
Device Protect Error
Word/byte Write Error
Word/Byte
V
No
Suspend
PP
Write
Range Error
Figure 7. Automated Word/byte Write Flowchart
Suspend Word/Byte
Yes
Write Loop
LHF16KAS
Repeat for subsequent word/byte writes.
SR full status check can be done after each word/byte write, or after a sequence of
SR.4,SR.3 and SR.1 are only cleared by the Clear Status Register
If error is detected, clear the Status Register before attempting
Write FFH after the last word/byte write operation to place device in
word/byte writes.
read array mode.
command in cases where multiple locations are written before
full status is checked.
retry or other error recovery.
Operation
Operation
Standby
Standby
Standby
Standby
Standby
Write
Read
Read
Write
Write
Bus
Bus
Setup Word/Byte
Word/Byte Write
Read Status
Command
Command
Register
Write
Data=70H
Addr=X
Data=40H or 10H
Addr=Location to Be Written
Data=Data to Be Written
Addr=Location to Be Written
1=WSM Ready
0=WSM Busy
Check SR.3
1=V
Check SR.1
1=Device Protect Detect
WP#=V
Check SR.4
Status Register Data
Check SR.7
1=WSM Ready
0=WSM Busy
Status Register Data
Check SR.7
Only required for systems
implementing lock-bit configuration
1=Data Write Error
PP
Error Detect
IL
,Block Lock-Bit is Set
Comments
Comments
Rev. 2.0
23

Related parts for LH28F160S3HT-L10