LH28F640BFHE-PBTLHGA Sharp Electronics, LH28F640BFHE-PBTLHGA Datasheet - Page 15

no-image

LH28F640BFHE-PBTLHGA

Manufacturer Part Number
LH28F640BFHE-PBTLHGA
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F640BFHE-PBTLHGA

Lead Free Status / Rohs Status
Supplier Unconfirmed
NOTES:
1. "WP#=0→1" means that WP# is driven to V
2. State transition from the current state [011] to the next state depends on the previous state.
3. When WP# is driven to V
4. In this state transitions table, assumes that lock configuration commands are not written in
Previous State
Other than
V
automatically locked.
previous, current and next state.
[110]
[110]
IL
.
-
-
-
-
-
-
(2)
(2)
Table 9. Block Locking State Transitions upon WP# Transition
[000]
[001]
[011]
[100]
[101]
[110]
State
[111]
Current State
IL
WP#
0
0
0
1
1
1
1
in [110] state, the state changes to [011] and the blocks are
LHF64FHG
DQ
0
0
1
0
0
1
1
1
IH
DQ
0
1
1
0
1
0
1
and "WP#=1→0" means that WP# is driven to
0
Result after WP# Transition (Next State)
WP#=0→1
[100]
[101]
[110]
[111]
-
-
-
-
(1)
(4)
WP#=1→0
[000]
[001]
[011]
[011]
-
-
-
-
(3)
(1)
Rev. 2.45
13

Related parts for LH28F640BFHE-PBTLHGA