JS28F128P30T85 Micron Technology Inc, JS28F128P30T85 Datasheet - Page 71

no-image

JS28F128P30T85

Manufacturer Part Number
JS28F128P30T85
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of JS28F128P30T85

Cell Type
NOR
Density
128Mb
Access Time (max)
85/17ns
Interface Type
Parallel/Serial
Boot Type
Top
Address Bus
23b
Operating Supply Voltage (typ)
1.8V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
1.7 to 2/8.5 to 9.5V
Sync/async
Async/Sync
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
1.7V
Operating Supply Voltage (max)
2V
Word Size
16b
Number Of Words
8M
Supply Current
28mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant
P30
Table 38: Example of CFI Structure Output of x16- Devices
A.1.2
Table 39: CFI Structure
Notes:
1.
2.
3.
A.1.3
Table 40: CFI Identification
August 2008
Order Number: 306666-12
Refer to the CFI Structure Output section and offset 28h for the detailed definition of offset address as a function of device
bus width and mode.
BA = Block Address beginning location (i.e., 08000h is block 1’s beginning location when the block size is 32-KWord).
Offset 15 defines “P” which points to the Primary Numonyx-specific Extended CFI Table.
00010h
00011h
00012h
00013h
00014h
00015h
00016h
00017h
00018h
Offset
A
00001-Fh Reserved
00010h
0001Bh
00027h
X
...
–A
CFI Structure Overview
The CFI command causes the flash component to display the Common Flash Interface
(CFI) CFI structure or “database.” The structure sub-sections and address locations are
summarized below.
Offset
Read CFI Identification String
The Identification String provides verification that the component supports the
Common Flash Interface specification. It also indicates the specification version and
supported vendor-specified command set(s).
P
0
(3)
Offset
10h
13h
15h
17h
19h
CFI query identification string
System interface information
Device geometry definition
Primary Intel-specific Extended Query Table
Hex Code
Word Addressing:
Length
P_ID
A_ID
P_ID
A_ID
0051
0052
0059
P
P
3
2
2
2
2
LO
...
HI
LO
LO
HI
HI
Sub-Section Name
Query-unique ASCII string “QRY“
Primary vendor command set and control interface ID code.
Extended Query Table primary algorithm address
Alternate vendor command set and control interface ID code.
Secondary algorithm Extended Query Table address.
16-bit ID code for vendor-specified algorithms
0000h means no second vendor-specified algorithm exists
0000h means none exists
D
15
–D
0
AltVendor
PrVendor
PrVendor
TblAdr
Value
ID #
ID #
"Q"
"R"
"Y"
...
Description
00010h
00011h
00012h
00013h
00014h
00015h
00016h
00017h
00018h
Offset
A
X
...
–A
Command set ID and vendor data offset
Device timing & voltage information
Flash device layout
Vendor-defined additional information specific
to the Primary Vendor Algorithm
Reserved for vendor-specific information
0
Hex Code
Byte Addressing:
P_ID
P_ID
P_ID
51
52
59
...
LO
LO
Description
HI
D
7
–D
0
(1)
Add.
13:
15:
17:
18:
19:
1A:
10:
11:
12:
14:
16:
PrVendor
Value
ID #
ID #
"Q"
"R"
"Y"
Code Value
...
Hex
--51
--52
--59
--01
--00
--0A
--01
--00
--00
--00
--00
Datasheet
"Q"
"R"
"Y"
71

Related parts for JS28F128P30T85