AT86RF211SAHWR E2V, AT86RF211SAHWR Datasheet - Page 39

no-image

AT86RF211SAHWR

Manufacturer Part Number
AT86RF211SAHWR
Description
Manufacturer
E2V
Datasheet

Specifications of AT86RF211SAHWR

Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Modulation Type
FSK
Product Depth (mm)
7mm
Product Length (mm)
7mm
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Compliant
Table 4-17.
Notes:
e2v semiconductors SAS 2008
Name
RXFS
XTALFQ
FSKBW
FSKPOL
DSREF
MOFFSET
ADDFEAT
1. The same ADC is used to measure the RSSI or V
2. The V
3. While V
4. Description of RSSI measurement with hysteresis mechanism: if the RSSI measurement is higher than the high RSSI level,
stopped (the previously-measured RSSI is kept in the STATUS register). This can disturb the reception process (if a thresh-
old is used for DATAMSG validation).Therefore, it is not recommended to measure V
DATAMSG is validated (high RSSI level = TRSSI + HRSSI). If the RSSI measure is lower than the low RSSI level, DATAMSG
is inhibited (low RSSI level = TRSSI - HRSSI). Between these two levels, DATAMSG validation depends on the previous
measurement.
Example:
TRSSI = 32 and HRSSI = 4 implies high RSSI level = 36 and Low RSSI level = 28
CTRL1 Detailed Description
Number of Bits
1
2
1
1
1
1
1
1
1
1
CC
CC
measurement cannot be done when the AT86RF211S is in power-down mode.
is being measured, it is possible to measure the DC output of the discriminator.
Comments
reserved, must be kept to reset value: 0
RX frequency selection
(00)
(01)
Reset value: (10)
Crystal frequency
0: 10.245 MHz (when IF1 = 10.7 MHz)
1: 20.945 MHz (when IF1 = 21.4 MHz); option not available
Reset value: 0
Discriminator range, inactive in AT86RF211S mode: report to DISCRANGE bits of DTR register
0: Narrow Discriminator BW
1: Standard Discriminator BW
Reset value: 1
Polarity of DATAMSG
0: inverted signal
1: direct signal
Reset value: 1
Data slicer reference voltage
0: external reference: SKFILT pin voltage
1: internal reference: DAC level voltage
Reset value: 1
reserved, must be kept to reset value 0
reserved, must be kept to reset value: 0
0: internal ADC sets to V
1: internal ADC sets to DISCOUT DC level measurement
Reset value: 0
0: no additional feature, RF211 mode
1: additional digital features selected, RF211S mode, in which the DTR length is extended to 32
bits, giving access to new additional features
Reset value: 0
2
2
: F0
: F1
(1)(2)(3)(4)
2
(Continued)
CC
CC
(10)
(11)
voltage. When the V
measurement
2
2
: F2
: F3
CC
voltage is measured, the RSSI measurement is
CC
in reception mode.
0894C–WIRE–11/08
AT86RF211S
39