F10-S30R Omron, F10-S30R Datasheet - Page 15

25C4243

F10-S30R

Manufacturer Part Number
F10-S30R
Description
25C4243
Manufacturer
Omron
Datasheet

Specifications of F10-S30R

Sensing Range
90mm To 110mm
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Supply Current Max
150mA
Supply Voltage Max
19.8VDC
Sensor Terminals
Cable
Leaded Process Compatible
No
Rohs Compliant
No
F10
3. Performing Measurement in Response to External Input Signals (RUN Mode)
Note:
22
Normal mode
Wide mode (plain measurement)
TRIG Mode
CONT Mode
(1) Set the mode selector to RUN.
The Sensor in TRIG mode is used for object measurement only
once in synchronization with the rising edge of the TRIG signal and
the result is output.
In CONT mode, the Sensor is in sensing operation repeatedly while
the CONT signal is ON. The measurement result is renewed once
per measurement cycle, and output.
Minimum ON width for the trigger signal is 1 ms.
The OUTPUT signal is stored until the measure-
ment results are refreshed.
ENAB signal:
OFF width is 10 ms in normal mode.
Turns ON when the OUTPUT signal is re-
freshed.
When the switch is set to RUN mode, measurements are made in response to external input signals.
Relationship between the F10 I/O terminal operations and ON/OFF indications in the timing charts are as shown in the following table.
Input
Output
F10-C20/C25 do not have banks 1 to 3.
TRIG (pink)
CONT (white)
S_TEACH (yellow)
S_TEACH (yellow)
M_TEACH (purple)
M_TEACH (purple)
BANK1 (gray) (see note)
BANK2 (green) (see note)
BANK3 (red) (see note)
OUTPUT (black)
OUTPUT (black)
ENAB (orange)
TRIG
OUTPUT
ENAB
OUTPUT
ENAB
Signal
3.6 ms max.
3.6 ms max.
ON
OFF
ON
OFF
Indication in timing charts
Measurement cycle: Tout
Normal mode: 7.2 ms max.
Wide mode: 14.4 ms max.
Plain measurement: 10.8 ms max.
GND
OPEN
GND
Vcc
NPN (F10-C20/C30/C50)
POINT
Measurement cycle: Tout
Normal mode: 3.6 ms
Wide mode: 10.8 ms
Plain measurement: 7.2 ms
Turning the Guide Light ON and OFF:
In RUN mode, even when synchronous measurement
is not being executed, the guide light will normally be
ON. It is possible to turn the guide light OFF (and ON
again) by pressing the UP selection button as required.
While the guide light is being turned ON or OFF, the
ENAB signal is turned OFF, and no external inputs can
be received.
The OUTPUT signal is turned OFF when the UP selec-
tion button is pressed.
Press and hold
down the UP
selection button.
OUTPUT
ENAB
Guide light
ON: Lit
OFF: Unlit
Vcc
OPEN
Vcc
GND
PNP (F10-C25/C35/C55)
0.7 s max.
F10