F10-S30R Omron, F10-S30R Datasheet - Page 7

25C4243

F10-S30R

Manufacturer Part Number
F10-S30R
Description
25C4243
Manufacturer
Omron
Datasheet

Specifications of F10-S30R

Sensing Range
90mm To 110mm
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Supply Current Max
150mA
Supply Voltage Max
19.8VDC
Sensor Terminals
Cable
Leaded Process Compatible
No
Rohs Compliant
No
F10
(1) Displays measurement values (degree of conformity with the
(2) ON: Lit
(3) Displays the threshold.
(4) Displays type of value displayed on the level indicator.
(5) Starts teaching.
(6) Changes the threshold value.
(7) TEACH: Teaching Mode
14
F10-C20/C25
(3) Threshold
(7) Mode
(5) Teach/
Amplifiers
(1) Level
F10-C20/C25
PATT (Pattern measurement): Degree of conformity with model
PLN (Plain measurement)
F10-C30/C35/C50/C55
p:
d:
a:
registered model).
OFF: Not lit
Switches display item.
Changes measurement item selection level for plain measure-
ment.
Changes bank number for F10-C30/C35/C50/C55.
MON:
RUN:
indicators
selector
(TEACH/
MON/RUN)
display
button
Also displays bank number for F10-C30/C35/C50/C55
indicators
Pattern measurement:
Plain measurement:
Plain measurement:
Monitor Mode
Run Mode
(9) DIP switch
DEV: Deviation level
AVE: Average density
Degree of conformity model
Deviation level
Difference from average density
(8) Measurement
(2) Result
(4) Status
(6) UP/DOWN
item selection
switch
indicator
selection
buttons
indicators
F10-C30/C35/C50/C55
(8) Measurement
(1) Level
(3) Threshold
(5) Teach/
item/bank num-
ber selection
switch
(8) S Changing Measurement Items
indicators
indicators
display
button
S Bank Selection Mode
Teaching status
(plain)
Pattern Measurement
Measures the degree with which the pattern and the
detected image match to differentiate OK and NG images.
Plain Measurement
Determines the deviation level and average density to
differentiate OK and NG images.
(F10-C30/C35/C50/C55)
PATTSPLN
PATTSPLN
PATTSPLN
(9) DIP switch
Plain
OK
PATT
PATT/BANK
PATT
PATT/BANK
PATT/BANK
Registered pattern
Sensing object
Color
NG
Automatically switches
between pattern mea-
surement and plain
measurement depend-
ing on the taught model.
Executes pattern
measurement only.
Enters the mode for
selecting and setting
the bank in TEACH
Mode.
Not available
with
F10-C30/C35.
Stain
(2) Result
(4) Status indi-
(6) UP/DOWN
(7) Mode
NG
indicator
cator/bank
number
display
selection
buttons
selector
(TEACH/
MON/RUN)
Pattern
NG
F10

Related parts for F10-S30R