PEF 82912 F V1.4 Infineon Technologies, PEF 82912 F V1.4 Datasheet - Page 76

no-image

PEF 82912 F V1.4

Manufacturer Part Number
PEF 82912 F V1.4
Description
IC MODULAR ISDN NT INTELL TQFP64
Manufacturer
Infineon Technologies
Series
Q-SMINT®r
Datasheets

Specifications of PEF 82912 F V1.4

Function
Second Generation Modular
Interface
ISDN
Mounting Type
Surface Mount
Package / Case
64-LFTQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Voltage - Supply
-
Power (watts)
-
Operating Temperature
-
Number Of Circuits
-
Other names
PEF82912FV1.4XT
PEF82912FV14XP
SP000007558
SP000007559
Table 14
2,3…
– ISW
– SW
– CRC Cyclic Redundancy Check
– EOC Embedded Operation Channel
– ACT Activation bit
– DEA Deactivation bit
– CSO Cold Start Only
– UOA U-Only Activation
– SAI
– FEBE Far-end Block Error
– PS1
– PS2
– NTM NT-Test Mode
– AIB
– NIB
– SCO Start on Command only bit
– 1
The principle signal flow is depicted in
grouped in bits that are covered by the CRC and bits that are not. After the CRC
generation the bits are arranged in the proper sequence according to the 2B1Q frame
format, encoded and finally transmitted.
In receive direction the data is first decoded, descrambled, deframed and handed over
for further processing.
Data Sheet
can be accessed by the system interface for proprietary use
Inverted Synchronization Word (quad):
Synchronization Word (quad):
S-Activity Indicator
Power Status Primary Source
Power Status Secondary Source PS2 = (1) –> Secondary power supply ok
Alarm Indication Bit
Network Indication Bit
(currently not defined by ANSI/ETSI)
7
8
U-Superframe Format (cont’d)
Fram-
ing
SW
SW
2B +
D
2B +
D
2B +
D
Overhead Bits (M1 – M6)
EOC
i3
EOC
i6
FEBE = (0) –> Far-end block error occurred
CSO = (1) –> NT-activation with cold start only
UOA = (0) –> U-only activated
NTM = (0) –> NT busy in test mode
ACT = (1) –> Layer 2 ready for communication
DEA = (0) –> LT informs NT that it will turn off
PS1 = (1) –> Primary power supply ok
d/m = data / message bit
SAI = (0) –> S-interface is deactivated
AIB = (0) –> Interruption (according to ANSI)
NIB = (1) –> no function (reserved for network use)
a
i
Figure 34
62
= address bit
= information (data / message)
EOC
i4
EOC
i7
LT- to NT dir. > /
– 3 – 3 + 3 + 3 + 3 – 3 + 3 – 3 – 3
+ 3 + 3 – 3 – 3 – 3 + 3 – 3 + 3 + 3
and
EOC
i5
EOC
i8
Figure
UOA /
SAI
AIB /
NIB
Functional Description
35. The data is first
PEF 82912/82913
CRC
11
< NT- to LT dir.
CRC9 CRC
2001-03-30
10
CRC
12

Related parts for PEF 82912 F V1.4