ATxmega192D3 Atmel Corporation, ATxmega192D3 Datasheet - Page 88

no-image

ATxmega192D3

Manufacturer Part Number
ATxmega192D3
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATxmega192D3

Flash (kbytes)
192 Kbytes
Pin Count
64
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
50
Ext Interrupts
50
Usb Speed
No
Usb Interface
No
Spi
5
Twi (i2c)
2
Uart
3
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
200
Analog Comparators
2
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Eeprom (bytes)
2048
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
5
Output Compare Channels
18
Input Capture Channels
18
Pwm Channels
18
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega192D3-AU
Manufacturer:
CYPRESS
Quantity:
101
Part Number:
ATxmega192D3-AU
Manufacturer:
ATMEL
Quantity:
70
Part Number:
ATxmega192D3-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192D3-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192D3-H
Manufacturer:
SQ
Quantity:
719
Part Number:
ATxmega192D3-MH
Manufacturer:
Atmel
Quantity:
565
33. Errata
33.1
33.1.1
8134I–AVR–12/10
ATxmega256D3, ATxmega192D3, ATxmega128D3, ATxmega64D3
rev. E
1. Bandgap voltage input for the ACs cannot be changed when used for both ACs
2. VCC voltage scaler for AC is non-linear
Bandgap voltage input for the ACs can not be changed when used for both ACs simultaneously
VCC voltage scaler for AC is non-linear
ADC gain stage cannot be used for single conversion
ADC has increased INL error for some operating conditions
ADC gain stage output range is limited to 2.4 V
ADC Event on compare match non-functional
ADC propagation delay is not correct when 8x -64x gain is used
Bandgap measurement with the ADC is non-functional when VCC is below 2.7V
Accuracy lost on first three samples after switching input to ADC gain stage
Configuration of PGM and CWCM not as described in XMEGA A Manual
PWM is not restarted properly after a fault in cycle-by-cycle mode
BOD will be enabled at any reset
EEPROM page buffer always written when NVM DATA0 is written
Pending full asynchronous pin change interrupts will not wake the device
Pin configuration does not affect Analog Comparator Output
NMI Flag for Crystal Oscillator Failure automatically cleared
Crystal start-up time required after power-save even if crystal is source for RTC
RTC Counter value not correctly read after sleep
Pending asynchronous RTC-interrupts will not wake up device
TWI Transmit collision flag not cleared on repeated start
Clearing TWI Stop Interrupt Flag may lock the bus
TWI START condition at bus timeout will cause transaction to be dropped
TWI Data Interrupt Flag (DIF) erroneously read as set
WDR instruction inside closed window will not issue reset
TWIE is not available
simultaneously
If the Bandgap voltage is selected as input for one Analog Comparator (AC) and then
selected/deselected as input for another AC, the first comparator will be affected for up to
1 µs and could potentially give a wrong comparison result.
Problem fix/Workaround
If the Bandgap is required for both ACs simultaneously, configure the input selection for both
ACs before enabling any of them.
The 6-bit VCC voltage scaler in the Analog Comparators is non-linear.