1600636-6 TE Connectivity, 1600636-6 Datasheet
1600636-6
Specifications of 1600636-6
Related parts for 1600636-6
1600636-6 Summary of contents
Page 1
Product Specification Multi-Beam XL* Cable Panel Mount and Squeeze-To-Release Receptacles 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics Multi- Beam XL* Cable Panel Mount and Squeeze-To-Release Receptacles. 1.2. Qualification When tests are ...
Page 2
Ratings Voltage: See Figure 1 ! Current: See Figure 2 ! Temperature: -20 to 105 ! Contact Type Signal .100 [2.54 mm] Power .200 [5.08 mm] Power .250 [6.35 mm] Power .300 [7.62 mm] Volts RMS (Safety Extra Low ...
Page 3
Test Description Contact resistance at rated current, power contacts. Insulation resistance. Withstanding voltage. Temperature rise vs current. Vibration, random. Mechanical shock. Durability. Mating force. Rev C Requirement 0.7 milliohm maximum, end of life. Wire Size Test Current (AWG) (amperes DC) ...
Page 4
Test Description Unmating force. Contact insertion force, power contacts. Contact retention, straight pull. Contact retention, angled pull. Housing lock strength, straight pull. 25 pounds minimum. Housing lock strength, angles pull. Rev C Requirement 8 ounce minimum per power contact. .7 ...
Page 5
Test Description Crimp tensile. Thermal shock. Humidity-temperature cycling. Temperature life. Mixed flowing gas. Shall meet visual requirements, show no physical damage, and meet requirements of additional NOTE tests as specified in the Product Qualification and Requalification Test Sequence shown in ...
Page 6
Product Qualification and Requalification Test Sequence Test or Examination Initial examination of product Low level contact resistance, signal and power contacts Low level contact resistance, power contacts only Contact resistance at rated current, power contacts Insulation resistance Withstanding voltage ...
Page 7
QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specimen Selection Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test group 1 shall consist of 6 mated pairs (panel mount ...
Page 8
Tolerance: Unless otherwise specified, ±.005 or ± 2 degrees as applicable. NOTE 2. Material: AISI Type 02 tool steel per Material Specification 100-15. 3. Heat Treat: Rockwell C50-55 4. Gage surface shall be clean of contaminates or lubricants. Rev ...
Page 9
Tolerance: Unless otherwise specified, ±.005 or ± 2 degrees as applicable. NOTE 2. Material: AISI Type 02 tool steel per Material Specification 100-15. 3. Heat Treat: Rockwell C50-55. Rev C Figure 6 Power Contact Tensile Test Clamp 108-2157 9 ...