1600636-6 TE Connectivity, 1600636-6 Datasheet - Page 5

1600636-6

Manufacturer Part Number
1600636-6
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 1600636-6

Product Series
XL
Connector Type
Connector Assembly
Termination Style
Panel
Mating Type
Blindmate
Guides
With
Mating Functionality
Mate First-Break Last
Voltage Rating (signal) (vac)
60
Voltage Rating (power) (vac)
300
Voltage Rating (power) (vdc)
200
Sequencing
Yes
Connector Configuration Orientation
Right-to-Left
Centerline, Dc Module (mm [in])
6.35 [0.250]
Centerline, Ac Module (mm [in])
7.62 [0.300]
Centerline, Matrix (mm [in])
2.54 x 2.54 [.100 x .100]
Contact Type
Socket
Connector Style
Receptacle
Housing Material
Thermoplastic - GF
Total Number Of Dc Power
12
Total Number Of Ac Power
4
Total Number Of Signal
24
Connector Contact Configuration (no. Of Pos./type)
4/AC Power, 24/Signal, 12/DC Power
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Application Use
Cable-to-Board
Rev C
Crimp tensile.
Thermal shock.
Humidity-temperature cycling.
Temperature life.
Mixed flowing gas.
NOTE
Test Description
Shall meet visual requirements, show no physical damage, and meet requirements of additional
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
4.
See Note.
See Note.
See Note.
See Note.
14 (dual crimp)
12 (dual crimp)
16 (dual crimp)
Wire Size
Wire Size
(AWG)
(AWG)
10
12
14
ENVIRONMENTAL
22
24
26
8
Power Contact
Signal Contact
Figure 3 (end)
Requirement
(Lbs min)
(Lbs min)
Tensile
Tensile
11.0
80
80
50
80
70
50
7.0
4.0
80
EIA-364-8.
Determine crimp tensile at a rate of
.5 inch per minute. Clamp contacts
as shown in Figure 6.
EIA-364-32.
Subject specimens to 36 cycles
between -20 and 105
EIA-364-31, Method III, Condition
B without cold shocks.
Subject specimens to 10 cycles (10
days) between 25 and 40
to 95% RH.
EIA-364-17, Method A, Test
Condition 4.
Subject mated specimens to 105
for 504 hours (21 days).
EIA-364-65, Class IIA (4 gas).
Subject mated specimens to
environmental Class IIA for 20
days.
Procedure
/
C .
108-2157
/
C at 80
5 of 9
/
C