1600636-6

Manufacturer Part Number
1600636-6
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 1600636-6

Product Series
XL
Connector Type
Connector Assembly
Termination Style
Panel
Mating Type
Blindmate
Guides
With
Mating Functionality
Mate First-Break Last
Voltage Rating (signal) (vac)
60
Voltage Rating (power) (vac)
300
Voltage Rating (power) (vdc)
200
Sequencing
Yes
Connector Configuration Orientation
Right-to-Left
Centerline, Dc Module (mm [in])
6.35 [0.250]
Centerline, Ac Module (mm [in])
7.62 [0.300]
Centerline, Matrix (mm [in])
2.54 x 2.54 [.100 x .100]
Contact Type
Socket
Connector Style
Receptacle
Housing Material
Thermoplastic - GF
Total Number Of Dc Power
12
Total Number Of Ac Power
4
Total Number Of Signal
24
Connector Contact Configuration (no. Of Pos./type)
4/AC Power, 24/Signal, 12/DC Power
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Application Use
Cable-to-Board
Rev C
Unmating force.
Contact insertion force, power
contacts.
Contact retention, straight pull.
Contact retention, angled pull.
Housing lock strength, straight pull. 25 pounds minimum.
Housing lock strength, angles pull.
Test Description
8 ounce minimum per power
contact.
.7 ounce minimum per signal
contact.
6 pounds maximum.
30 pounds minimum for power
contact.
3 pounds minimum for signal
contact.
Figure 3 (cont)
Requirement
EIA-364-13.
Measure force necessary to
unmate specimens at a maximum
rate of 1 inch per minute. Size
signal contacts 3 times using gage
1, then insert gage 2 and measure
force necessary to separate.
See Figure 5.
EIA-364-5.
Measure force necessary to insert
contact into housing.
EIA-364-29.
Apply axial load to wire, as crimped
to contacts. Power contact
retention shall be qualified with
TPA lock and primary lance(s)
engaged. Signal contact retention
shall be qualified in 2 independent
modes: 1) primary lance only: and
2) secondary TPA lock only.
Signal TPA lock shall withstand 3
pounds minimum on a singly
loaded wire.
Apply load to single wires at a 45
degree angle in 4 directions from
normal exit plane of cable. Both
power and signal contact shall be
qualified with TPA locks and
primary lance(s) engaged.
EIA-364-98.
Apply axial force to mated pair
using securely mounted vertical
header (4-40 cap screw and nut
through mounting hole and printed
circuit board). Apply force in
straight pull in direction normal to
plane of cable entrance.
Apply load to wire bundle of mated
pair at a 45 degree angle in 4
directions from the normal exit
plane of the cable connector with
the mated vertical header securely
mounted.
Procedure
108-2157
4 of 9