71M6511 Maxim, 71M6511 Datasheet - Page 73

no-image

71M6511

Manufacturer Part Number
71M6511
Description
The 71M6511 and 71M6511H are highly integrated SoCs with an MPU core, RTC, flash, and LCD driver
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6511-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71M6511-IGT/F
Manufacturer:
ST
Quantity:
1 500
Part Number:
71M6511-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6511-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6511H-IGT/F
Manufacturer:
PERICOM
Quantity:
1 200
Part Number:
71M6511H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6511H-IGTR/F
Manufacturer:
MAXIM
Quantity:
101
Part Number:
71M6511H-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Current Shunt Variables
Input variables: IA_SHUNT and IB_SHUNT can configure the current inputs to accept shunt resistor sensors. In this case the
CE provides an additional gain of 8 to the current inputs. This will enable the pulse rate to change by 8 times. In order to
maintain a normal pulse rate WRATE may have to be decreased by 8 times. Whenever IA_SHUNT or IB_SHUNT are set to 1 or
a positive number, In_8 is assigned a value of 8 in the equation for Kh.
CE Calibration Parameters
The table below lists the parameters that are typically entered to affect calibration of meter accuracy.
Page: 73 of 98
Address
Address
CE
2A
2B
2C
CE
10
A
B
C
D
E
8
9
F
A Maxim Integrated Products Brand
RESERVED
RESERVED
RESERVED
RESERVED
PHADJ_A
IA_SHUNT
IB_SHUNT
CAL_VA
CAL_IA
CAL_IB
Name
Name
Default
16384
16384
16384
Default
0
0
0
-1
-1
© 2005–2010 Teridian Semiconductor Corporation
Description
These constants control the gain of their respective channels. The nominal
value for each parameters is 2
proportional to its CAL parameter. Thus, if the gain of a channel is 1% slow,
CAL should be scaled by 1/(1 – 0.01).
These two constants control the CT phase compensation. No compensation
occurs when PHADJ_X = 0. As PHADJ_X is increased, more compensation
(lag) is introduced. Range: ±2
angle Φ:
b
PHADJ
a
c
Description
When +1, these variables increase the respective current gain by 8. The
gain factor controlled by In_SHUNT is referred to as In_8 throughout this
document. Allowed values are 1 or –1. For example, if IB_SHUNT=-1, IB_8
= 1, if IB_SHUNT = 1, IB_8 = 8.
IA_SHUNT corresponds to IA_8, IB_SHUNT corresponds to IB_8.
=
=
=
1
1
1 (
+
1 (
1 (
_
2
X
9
2
2
)
=
sin(
9
9
2
)
)
20
cos(
2
2
Single-Phase Energy Meter IC
b
π
a
2
F
2
1 (
0
c
T
π
TAN
F
TAN
)
0
2
T
Φ
15
71M6511/71M6511H
14
9
)
Φ
)
– 1. If it is desired to delay the current by the
= 16384. The gain of each channel is directly
cos(
DATA SHEET
2
π
F
0
T
)
NOVEMBER 2010
F
0
T
=
F
F
0
S
V2.7

Related parts for 71M6511