PM8621-BI PMC-Sierra, Inc., PM8621-BI Datasheet - Page 124

no-image

PM8621-BI

Manufacturer Part Number
PM8621-BI
Description
Driver, NSE/SBS Narrowband Chipset Driver
Manufacturer
PMC-Sierra, Inc.
Datasheet
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-2021248, Issue 1
Outputs
Returns
Valid States
Side Effects
Prototype
Inputs
Outputs
Returns
Configuring LVDS link parameters: nbcsLkcCfg
This function allows user to configure the parameters for a specified link in the SBS and NSE
devices. Parameters applicable to both the NSE and SBS are: J0 byte insertion, and path
termination mode.
This function also accepts group handle and acts on all members in the group. If the group
contains mixed devices, the only valid entry for
and protect links in a SBS and to all ports in a NSE device.
opMode
None
Success =
Failure =
NBCS_ACTIVE, NBCS_INACTIVE
None
INT4 nbcsLkcCfg(sNBCS_HNDL handle, UINT1
linkDesc, sNBCS_CFG_LKC *pCfg)
handle
linkDesc
pCfg
None
Success =
Failure =
NBCS_ERR_INVALID_ARG
NBCS_ERR_INVALID_ARG
NBCS_ERR_INVALID_DEVICE_STATE
NBCS_ERR_DEV_ABSENT
NBCS_ERR_INVALID_DEVICE_STATE
NBCS_ERR_DEV_ABSENT
NBCS_ERR_INVALID_DEV
NBCS_ERR_INVALID_DEV
NBCS_SUCCESS
NBCS_SUCCESS
: For SBS: 0 = disabled, 1 = enabled
: device/group handle (from
: For SBS: 0 = working link, 1 =
: pointer to the configuration structure
transmit and receive.
without selecting as active link on
receive side, 2 = enabled and selects
the link as active on receive side.
For NSE: operating mode: 0 =
standby, 1 = normal, 2 = reset
or
protection link; FFh = all links. For
NSE devices, link number ranges from
0-11 for NSE-8G and from 0-31 for
NSE-20G. A ffh indicates all ports.
nbcsGroupAdd
linkDesc
Narrowband Chipset Device Driver Manual
is ffh, which applies to all working
);
Application Programming Interface
nbcsAdd
124